Skip to main content

Structured Illumination Microscopy and a Quantitative Image Analysis for the Detection of Positive Margins in a Pre-Clinical Genetically Engineered Mouse Model of Sarcoma.

Publication ,  Dataset
Fu, HL; Mueller, JL; Whitley, MJ; Cardona, DM; Willett, RM; Kirsch, DG; Brown, JQ; Ramanujam, N
2016

Intraoperative assessment of surgical margins is critical to ensuring residual tumor does not remain in a patient. Previously, we developed a fluorescence structured illumination microscope (SIM) system with a single-shot field of view (FOV) of 2.1 × 1.6 mm (3.4 mm2) and sub-cellular resolution (4.4 μm). The goal of this study was to test the utility of this technology for the detection of residual disease in a genetically engineered mouse model of sarcoma. Primary soft tissue sarcomas were generated in the hindlimb and after the tumor was surgically removed, the relevant margin was stained with acridine orange (AO), a vital stain that brightly stains cell nuclei and fibrous tissues. The tissues were imaged with the SIM system with the primary goal of visualizing fluorescent features from tumor nuclei. Given the heterogeneity of the background tissue (presence of adipose tissue and muscle), an algorithm known as maximally stable extremal regions (MSER) was optimized and applied to the images to specifically segment nuclear features. A logistic regression model was used to classify a tissue site as positive or negative by calculating area fraction and shape of the segmented features that were present and the resulting receiver operator curve (ROC) was generated by varying the probability threshold. Based on the ROC curves, the model was able to classify tumor and normal tissue with 77% sensitivity and 81% specificity (Youden's index). For an unbiased measure of the model performance, it was applied to a separate validation dataset that resulted in 73% sensitivity and 80% specificity. When this approach was applied to representative whole margins, for a tumor probability threshold of 50%, only 1.2% of all regions from the negative margin exceeded this threshold, while over 14.8% of all regions from the positive margin exceeded this threshold.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

DOI

Publication Date

2016

Related Subject Headings

  • Sarcoma
  • Microscopy, Fluorescence
  • Mice
  • Genetic Engineering
  • General Science & Technology
  • Disease Models, Animal
  • Animals
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Fu, H. L., Mueller, J. L., Whitley, M. J., Cardona, D. M., Willett, R. M., Kirsch, D. G., … Ramanujam, N. (2016). Structured Illumination Microscopy and a Quantitative Image Analysis for the Detection of Positive Margins in a Pre-Clinical Genetically Engineered Mouse Model of Sarcoma. https://doi.org/10.1371/journal.pone.0147006
Fu, Henry L., Jenna L. Mueller, Melodi J. Whitley, Diana M. Cardona, Rebecca M. Willett, David G. Kirsch, J Quincy Brown, and Nimmi Ramanujam. “Structured Illumination Microscopy and a Quantitative Image Analysis for the Detection of Positive Margins in a Pre-Clinical Genetically Engineered Mouse Model of Sarcoma.,” 2016. https://doi.org/10.1371/journal.pone.0147006.

DOI

Publication Date

2016

Related Subject Headings

  • Sarcoma
  • Microscopy, Fluorescence
  • Mice
  • Genetic Engineering
  • General Science & Technology
  • Disease Models, Animal
  • Animals