Skip to main content
Journal cover image

Real-time measurements of PM2.5 and ozone to assess the effectiveness of residential indoor air filtration in Shanghai homes.

Publication ,  Journal Article
Barkjohn, KK; Norris, C; Cui, X; Fang, L; Zheng, T; Schauer, JJ; Li, Z; Zhang, Y; Black, M; Zhang, JJ; Bergin, MH
Published in: Indoor air
January 2021

Portable air cleaners are increasingly used in polluted areas in an attempt to reduce human exposure; however, there has been limited work characterizing their effectiveness at reducing exposure. With this in mind, we recruited forty-three children with asthma from suburban Shanghai and deployed air cleaners (with HEPA and activated carbon filters) in their bedrooms. During both 2-week filtration and non-filtration periods, low-cost PM2.5 and O3 air monitors were used to measure pollutants indoors, outdoors, and for personal exposure. Indoor PM2.5 concentrations were reduced substantially with the use of air cleaners, from 34 ± 17 to 10 ± 8 µg/m3 , with roughly 80% of indoor PM2.5 estimated to come from outdoor sources. Personal exposure to PM2.5 was reduced from 40 ± 17 to 25 ± 14 µg/m3 . The more modest reductions in personal exposure and high contribution of outdoor PM2.5 to indoor concentrations highlight the need to reduce outdoor PM2.5 and/or to clean indoor air in multiple locations. Indoor O3 concentrations were generally low (mean = 8±4 ppb), and no significant difference was seen by filtration status. The concentrations of pollutants and the air cleaner effectiveness were highly variable over time and across homes, highlighting the usefulness of real-time air monitors for understanding individual exposure reduction strategies.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Indoor air

DOI

EISSN

1600-0668

ISSN

0905-6947

Publication Date

January 2021

Volume

31

Issue

1

Start / End Page

74 / 87

Related Subject Headings

  • Particulate Matter
  • Particle Size
  • Ozone
  • Humans
  • Filtration
  • Environmental Monitoring
  • China
  • Child
  • Building & Construction
  • Air Pollution, Indoor
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Barkjohn, K. K., Norris, C., Cui, X., Fang, L., Zheng, T., Schauer, J. J., … Bergin, M. H. (2021). Real-time measurements of PM2.5 and ozone to assess the effectiveness of residential indoor air filtration in Shanghai homes. Indoor Air, 31(1), 74–87. https://doi.org/10.1111/ina.12716
Barkjohn, Karoline K., Christina Norris, Xiaoxing Cui, Lin Fang, Tongshu Zheng, James J. Schauer, Zhen Li, et al. “Real-time measurements of PM2.5 and ozone to assess the effectiveness of residential indoor air filtration in Shanghai homes.Indoor Air 31, no. 1 (January 2021): 74–87. https://doi.org/10.1111/ina.12716.
Barkjohn KK, Norris C, Cui X, Fang L, Zheng T, Schauer JJ, et al. Real-time measurements of PM2.5 and ozone to assess the effectiveness of residential indoor air filtration in Shanghai homes. Indoor air. 2021 Jan;31(1):74–87.
Barkjohn, Karoline K., et al. “Real-time measurements of PM2.5 and ozone to assess the effectiveness of residential indoor air filtration in Shanghai homes.Indoor Air, vol. 31, no. 1, Jan. 2021, pp. 74–87. Epmc, doi:10.1111/ina.12716.
Barkjohn KK, Norris C, Cui X, Fang L, Zheng T, Schauer JJ, Li Z, Zhang Y, Black M, Zhang JJ, Bergin MH. Real-time measurements of PM2.5 and ozone to assess the effectiveness of residential indoor air filtration in Shanghai homes. Indoor air. 2021 Jan;31(1):74–87.
Journal cover image

Published In

Indoor air

DOI

EISSN

1600-0668

ISSN

0905-6947

Publication Date

January 2021

Volume

31

Issue

1

Start / End Page

74 / 87

Related Subject Headings

  • Particulate Matter
  • Particle Size
  • Ozone
  • Humans
  • Filtration
  • Environmental Monitoring
  • China
  • Child
  • Building & Construction
  • Air Pollution, Indoor