Skip to main content
Journal cover image

Prostate Cancer Detection Using 3-D Shear Wave Elasticity Imaging.

Publication ,  Journal Article
Morris, DC; Chan, DY; Palmeri, ML; Polascik, TJ; Foo, W-C; Nightingale, KR
Published in: Ultrasound Med Biol
July 2021

Transrectal ultrasound (TRUS) B-mode imaging provides insufficient sensitivity and specificity for prostate cancer (PCa) targeting when used for biopsy guidance. Shear wave elasticity imaging (SWEI) is an elasticity imaging technique that has been commercially implemented and is sensitive and specific for PCa. We have developed a SWEI system capable of 3-D data acquisition using a dense acoustic radiation force (ARF) push approach that leads to enhanced shear wave signal-to-noise ratio compared with that of the commercially available SWEI systems and facilitates screening of the entire gland before biopsy. Additionally, we imaged and assessed 36 patients undergoing radical prostatectomy using 3-D SWEI and determined a shear wave speed threshold separating PCa from healthy prostate tissue with sensitivities and specificities akin to those for multiparametric magnetic resonance imaging fusion biopsy. The approach measured the mean shear wave speed in each prostate region to be 4.8 m/s (Young's modulus E = 69.1 kPa) in the peripheral zone, 5.3 m/s (E = 84.3 kPa) in the central gland and 6.0 m/s (E = 108.0 kPa) for PCa with statistically significant (p < 0.0001) differences among all regions. Three-dimensional SWEI receiver operating characteristic analyses identified a threshold of 5.6 m/s (E = 94.1 kPa) to separate PCa from healthy tissue with a sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and area under the curve (AUC) of 81%, 82%, 69%, 89% and 0.84, respectively. Additionally, a shear wave speed ratio was assessed to normalize for tissue compression and patient variability, which yielded a threshold of 1.11 to separate PCa from healthy prostate tissue and was accompanied by a substantial increase in specificity, PPV and AUC, where the sensitivity, specificity, PPV, NPV and AUC were 75%, 90%, 79%, 88% and 0.90, respectively. This work illustrates the feasibility of using 3-D SWEI data to detect and localize PCa and demonstrates the benefits of normalizing for applied compression during data acquisition for use in biopsy targeting studies.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Ultrasound Med Biol

DOI

EISSN

1879-291X

Publication Date

July 2021

Volume

47

Issue

7

Start / End Page

1670 / 1680

Location

England

Related Subject Headings

  • Sensitivity and Specificity
  • Retrospective Studies
  • Prostatic Neoplasms
  • Male
  • Imaging, Three-Dimensional
  • Humans
  • Elasticity Imaging Techniques
  • Acoustics
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Morris, D. C., Chan, D. Y., Palmeri, M. L., Polascik, T. J., Foo, W.-C., & Nightingale, K. R. (2021). Prostate Cancer Detection Using 3-D Shear Wave Elasticity Imaging. Ultrasound Med Biol, 47(7), 1670–1680. https://doi.org/10.1016/j.ultrasmedbio.2021.02.006
Morris, D Cody, Derek Y. Chan, Mark L. Palmeri, Thomas J. Polascik, Wen-Chi Foo, and Kathryn R. Nightingale. “Prostate Cancer Detection Using 3-D Shear Wave Elasticity Imaging.Ultrasound Med Biol 47, no. 7 (July 2021): 1670–80. https://doi.org/10.1016/j.ultrasmedbio.2021.02.006.
Morris DC, Chan DY, Palmeri ML, Polascik TJ, Foo W-C, Nightingale KR. Prostate Cancer Detection Using 3-D Shear Wave Elasticity Imaging. Ultrasound Med Biol. 2021 Jul;47(7):1670–80.
Morris, D. Cody, et al. “Prostate Cancer Detection Using 3-D Shear Wave Elasticity Imaging.Ultrasound Med Biol, vol. 47, no. 7, July 2021, pp. 1670–80. Pubmed, doi:10.1016/j.ultrasmedbio.2021.02.006.
Morris DC, Chan DY, Palmeri ML, Polascik TJ, Foo W-C, Nightingale KR. Prostate Cancer Detection Using 3-D Shear Wave Elasticity Imaging. Ultrasound Med Biol. 2021 Jul;47(7):1670–1680.
Journal cover image

Published In

Ultrasound Med Biol

DOI

EISSN

1879-291X

Publication Date

July 2021

Volume

47

Issue

7

Start / End Page

1670 / 1680

Location

England

Related Subject Headings

  • Sensitivity and Specificity
  • Retrospective Studies
  • Prostatic Neoplasms
  • Male
  • Imaging, Three-Dimensional
  • Humans
  • Elasticity Imaging Techniques
  • Acoustics
  • 3202 Clinical sciences
  • 1103 Clinical Sciences