Skip to main content

Automated Identification of Referable Retinal Pathology in Teleophthalmology Setting.

Publication ,  Journal Article
Gao, Q; Amason, J; Cousins, S; Pajic, M; Hadziahmetovic, M
Published in: Transl Vis Sci Technol
May 3, 2021

PURPOSE: This study aims to meet a growing need for a fully automated, learning-based interpretation tool for retinal images obtained remotely (e.g. teleophthalmology) through different imaging modalities that may include imperfect (uninterpretable) images. METHODS: A retrospective study of 1148 optical coherence tomography (OCT) and color fundus photography (CFP) retinal images obtained using Topcon's Maestro care unit on 647 patients with diabetes. To identify retinal pathology, a Convolutional Neural Network (CNN) with dual-modal inputs (i.e. CFP and OCT images) was developed. We developed a novel alternate gradient descent algorithm to train the CNN, which allows for the use of uninterpretable CFP/OCT images (i.e. ungradable images that do not contain sufficient image biomarkers for the reviewer to conclude absence or presence of retinal pathology). Specifically, a 9:1 ratio to split the training and testing dataset was used for training and validating the CNN. Paired CFP/OCT inputs (obtained from a single eye of a patient) were grouped as retinal pathology negative (RPN; 924 images) in the absence of retinal pathology in both imaging modalities, or if one of the imaging modalities was uninterpretable and the other without retinal pathology. If any imaging modality exhibited referable retinal pathology, the corresponding CFP/OCT inputs were deemed retinal pathology positive (RPP; 224 images) if any imaging modality exhibited referable retinal pathology. RESULTS: Our approach achieved 88.60% (95% confidence interval [CI] = 82.76% to 94.43%) accuracy in identifying pathology, along with the false negative rate (FNR) of 12.28% (95% CI = 6.26% to 18.31%), recall (sensitivity) of 87.72% (95% CI = 81.69% to 93.74%), specificity of 89.47% (95% CI = 83.84% to 95.11%), and area under the curve of receiver operating characteristic (AUC-ROC) was 92.74% (95% CI = 87.71% to 97.76%). CONCLUSIONS: Our model can be successfully deployed in clinical practice to facilitate automated remote retinal pathology identification. TRANSLATIONAL RELEVANCE: A fully automated tool for early diagnosis of retinal pathology might allow for earlier treatment and improved visual outcomes.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Transl Vis Sci Technol

DOI

EISSN

2164-2591

Publication Date

May 3, 2021

Volume

10

Issue

6

Start / End Page

30

Location

United States

Related Subject Headings

  • Tomography, Optical Coherence
  • Telemedicine
  • Retrospective Studies
  • Retina
  • Ophthalmology
  • Humans
  • 3212 Ophthalmology and optometry
  • 1113 Opthalmology and Optometry
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Gao, Q., Amason, J., Cousins, S., Pajic, M., & Hadziahmetovic, M. (2021). Automated Identification of Referable Retinal Pathology in Teleophthalmology Setting. Transl Vis Sci Technol, 10(6), 30. https://doi.org/10.1167/tvst.10.6.30
Gao, Qitong, Joshua Amason, Scott Cousins, Miroslav Pajic, and Majda Hadziahmetovic. “Automated Identification of Referable Retinal Pathology in Teleophthalmology Setting.Transl Vis Sci Technol 10, no. 6 (May 3, 2021): 30. https://doi.org/10.1167/tvst.10.6.30.
Gao Q, Amason J, Cousins S, Pajic M, Hadziahmetovic M. Automated Identification of Referable Retinal Pathology in Teleophthalmology Setting. Transl Vis Sci Technol. 2021 May 3;10(6):30.
Gao, Qitong, et al. “Automated Identification of Referable Retinal Pathology in Teleophthalmology Setting.Transl Vis Sci Technol, vol. 10, no. 6, May 2021, p. 30. Pubmed, doi:10.1167/tvst.10.6.30.
Gao Q, Amason J, Cousins S, Pajic M, Hadziahmetovic M. Automated Identification of Referable Retinal Pathology in Teleophthalmology Setting. Transl Vis Sci Technol. 2021 May 3;10(6):30.

Published In

Transl Vis Sci Technol

DOI

EISSN

2164-2591

Publication Date

May 3, 2021

Volume

10

Issue

6

Start / End Page

30

Location

United States

Related Subject Headings

  • Tomography, Optical Coherence
  • Telemedicine
  • Retrospective Studies
  • Retina
  • Ophthalmology
  • Humans
  • 3212 Ophthalmology and optometry
  • 1113 Opthalmology and Optometry
  • 0903 Biomedical Engineering