Skip to main content
Journal cover image

Guidance of cardiac pacemaker leads using real time 3D ultrasound: feasibility studies.

Publication ,  Journal Article
Smith, SW; Booi, RC; Light, ED; Merdes, CL; Wolf, PD
Published in: Ultrasonic imaging
April 2002

We investigated the feasibility of the guidance of pacemaker lead implantation using the pacemaker lead stylet as an acoustic wave-guide combined with real time 3D ultrasound imaging. In one approach, with a 2.5 MHz transducer coupled to a stylet of a pacemaker lead, we used the stylet as a transmitter to track the vibrating tip in a 3D ultrasound scan. In another approach, we connected the stylet to a piezoelectric actuator vibrating in the range 0.5-5 kHz so that the tip of the stylet was imaged using the color Doppler feature of the real time 3D ultrasound scanner. In both approaches, tracking of the isolated stylet showed good accuracy. However, neither approach offered sufficient signal-to-noise ratio to detect the vibration within the lumen of an intact pacemaker lead.

Duke Scholars

Published In

Ultrasonic imaging

DOI

EISSN

1096-0910

ISSN

0161-7346

Publication Date

April 2002

Volume

24

Issue

2

Start / End Page

119 / 128

Related Subject Headings

  • Ultrasonography, Doppler
  • Sheep
  • Pacemaker, Artificial
  • Models, Animal
  • Imaging, Three-Dimensional
  • Feasibility Studies
  • Electrodes, Implanted
  • Animals
  • Acoustics
  • 4003 Biomedical engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Smith, S. W., Booi, R. C., Light, E. D., Merdes, C. L., & Wolf, P. D. (2002). Guidance of cardiac pacemaker leads using real time 3D ultrasound: feasibility studies. Ultrasonic Imaging, 24(2), 119–128. https://doi.org/10.1177/016173460202400205
Smith, Stephen W., Rebecca C. Booi, Edward D. Light, Christine L. Merdes, and Patrick D. Wolf. “Guidance of cardiac pacemaker leads using real time 3D ultrasound: feasibility studies.Ultrasonic Imaging 24, no. 2 (April 2002): 119–28. https://doi.org/10.1177/016173460202400205.
Smith SW, Booi RC, Light ED, Merdes CL, Wolf PD. Guidance of cardiac pacemaker leads using real time 3D ultrasound: feasibility studies. Ultrasonic imaging. 2002 Apr;24(2):119–28.
Smith, Stephen W., et al. “Guidance of cardiac pacemaker leads using real time 3D ultrasound: feasibility studies.Ultrasonic Imaging, vol. 24, no. 2, Apr. 2002, pp. 119–28. Epmc, doi:10.1177/016173460202400205.
Smith SW, Booi RC, Light ED, Merdes CL, Wolf PD. Guidance of cardiac pacemaker leads using real time 3D ultrasound: feasibility studies. Ultrasonic imaging. 2002 Apr;24(2):119–128.
Journal cover image

Published In

Ultrasonic imaging

DOI

EISSN

1096-0910

ISSN

0161-7346

Publication Date

April 2002

Volume

24

Issue

2

Start / End Page

119 / 128

Related Subject Headings

  • Ultrasonography, Doppler
  • Sheep
  • Pacemaker, Artificial
  • Models, Animal
  • Imaging, Three-Dimensional
  • Feasibility Studies
  • Electrodes, Implanted
  • Animals
  • Acoustics
  • 4003 Biomedical engineering