We present the design, testing, and evaluation of a 16 channel wearable telemetry system to facilitate multichannel single unit recordings from freely moving test subjects. Our design is comprised of (1) a 16-channel analog front end board to condition and sample signals derived from implanted neural electrodes, (2) a digital board for processing and buffering the digitized waveforms, and (3) an index-card sized 486 PC equipped with an IEEE 802.11b wireless ethernet card. Digitized data (up to 12 bits of resolution at 31.25k samples/s per channel) is transferred to the PC and sent to a nearby host computer on a wireless local area network. Up to 12 of the 16 channels were transmitted simultaneously for sustained periods at a range of 9 m. The device measures 5.1 cm x 8.1 cm x 12.4 cm, weighs 235 g, and is powered from rechargeable lithium ion batteries with a lifespan of 45 min at maximum transmission power. The device was successfully used to record signals from awake, chronically implanted macaque and owl monkeys.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Neurosci Methods

DOI

ISSN

0165-0270

Publication Date

February 15, 2004

Volume

133

Issue

1-2

Start / End Page

33 / 38

Location

Netherlands

Related Subject Headings

  • Telemetry
  • Signal Processing, Computer-Assisted
  • Neurons
  • Neurology & Neurosurgery
  • Microelectrodes
  • Haplorhini
  • Equipment Design
  • Electrophysiology
  • Electronics, Medical
  • Animals
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Obeid, I., Nicolelis, M. A. L., & Wolf, P. D. (2004). A multichannel telemetry system for single unit neural recordings. J Neurosci Methods, 133(1–2), 33–38. https://doi.org/10.1016/j.jneumeth.2003.09.023
Obeid, Iyad, Miguel A. L. Nicolelis, and Patrick D. Wolf. “A multichannel telemetry system for single unit neural recordings.J Neurosci Methods 133, no. 1–2 (February 15, 2004): 33–38. https://doi.org/10.1016/j.jneumeth.2003.09.023.
Obeid I, Nicolelis MAL, Wolf PD. A multichannel telemetry system for single unit neural recordings. J Neurosci Methods. 2004 Feb 15;133(1–2):33–8.
Obeid, Iyad, et al. “A multichannel telemetry system for single unit neural recordings.J Neurosci Methods, vol. 133, no. 1–2, Feb. 2004, pp. 33–38. Pubmed, doi:10.1016/j.jneumeth.2003.09.023.
Obeid I, Nicolelis MAL, Wolf PD. A multichannel telemetry system for single unit neural recordings. J Neurosci Methods. 2004 Feb 15;133(1–2):33–38.
Journal cover image

Published In

J Neurosci Methods

DOI

ISSN

0165-0270

Publication Date

February 15, 2004

Volume

133

Issue

1-2

Start / End Page

33 / 38

Location

Netherlands

Related Subject Headings

  • Telemetry
  • Signal Processing, Computer-Assisted
  • Neurons
  • Neurology & Neurosurgery
  • Microelectrodes
  • Haplorhini
  • Equipment Design
  • Electrophysiology
  • Electronics, Medical
  • Animals