A mathematical model platform for optimizing a multiprojection breast imaging system.

Publication ,  Journal Article
Chawla, AS; Samei, E; Saunders, RS; Lo, JY; Baker, JA
Published in: Med Phys
April 2008

Multiprojection imaging is a technique in which a plurality of digital radiographic images of the same patient are acquired within a short interval of time from slightly different angles. Information from each image is combined to determine the final diagnosis. Projection data are either reconstructed into slices as in the case of tomosynthesis or analyzed directly as in the case of multiprojection correlation imaging technique, thereby avoiding reconstruction artifacts. In this study, the authors investigated the optimum geometry of acquisitions of a multiprojection breast correlation imaging system in terms of the number of projections and their total angular span that yield maximum performance in a task that models clinical decision. Twenty-five angular projections of each breast from 82 human subjects in our breast tomosynthesis database were each supplemented with a simulated 3 mm mass. An approach based on Laguerre-Gauss channelized Hotelling observer was developed to assess the detectability of the mass in terms of receiver operating characteristic (ROC) curves. Two methodologies were developed to integrate results from individual projections into one combined ROC curve as the overall figure of merit. To optimize the acquisition geometry, different components of acquisitions were changed to investigate which one of the many possible configurations maximized the area under the combined ROC curve. Optimization was investigated under two acquisition dose conditions corresponding to a fixed total dose delivered to the patient and a variable dose condition, based on the number of projections used. In either case, the detectability was dependent on the number of projections used, the total angular span of those projections, and the acquisition dose level. In the first case, the detectability approximately followed a bell curve as a function of the number of projections with the maximum between 8 and 16 projections spanning angular arcs of about 23 degrees-45 degrees, respectively. In the second case, the detectability increased with the number of projections approaching an asymptote at 11-17 projections for an angular span of about 45 degrees. These results indicate the inherent information content of the multi-projection image data reflecting the relative role of quantum and anatomical noise in multiprojection breast imaging. The optimization scheme presented here may be applied to any multiprojection imaging modalities and may be extended by including reconstruction in the case of digital breast tomosynthesis and breast computed tomography.

Duke Scholars

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

April 2008

Volume

35

Issue

4

Start / End Page

1337 / 1345

Location

United States

Related Subject Headings

  • Subtraction Technique
  • Software
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiographic Image Interpretation, Computer-Assisted
  • Radiographic Image Enhancement
  • Nuclear Medicine & Medical Imaging
  • Models, Biological
  • Mammography
  • Imaging, Three-Dimensional
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chawla, A. S., Samei, E., Saunders, R. S., Lo, J. Y., & Baker, J. A. (2008). A mathematical model platform for optimizing a multiprojection breast imaging system. Med Phys, 35(4), 1337–1345. https://doi.org/10.1118/1.2885367
Chawla, Amarpreet S., Ehsan Samei, Robert S. Saunders, Joseph Y. Lo, and Jay A. Baker. “A mathematical model platform for optimizing a multiprojection breast imaging system.Med Phys 35, no. 4 (April 2008): 1337–45. https://doi.org/10.1118/1.2885367.
Chawla AS, Samei E, Saunders RS, Lo JY, Baker JA. A mathematical model platform for optimizing a multiprojection breast imaging system. Med Phys. 2008 Apr;35(4):1337–45.
Chawla, Amarpreet S., et al. “A mathematical model platform for optimizing a multiprojection breast imaging system.Med Phys, vol. 35, no. 4, Apr. 2008, pp. 1337–45. Pubmed, doi:10.1118/1.2885367.
Chawla AS, Samei E, Saunders RS, Lo JY, Baker JA. A mathematical model platform for optimizing a multiprojection breast imaging system. Med Phys. 2008 Apr;35(4):1337–1345.

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

April 2008

Volume

35

Issue

4

Start / End Page

1337 / 1345

Location

United States

Related Subject Headings

  • Subtraction Technique
  • Software
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiographic Image Interpretation, Computer-Assisted
  • Radiographic Image Enhancement
  • Nuclear Medicine & Medical Imaging
  • Models, Biological
  • Mammography
  • Imaging, Three-Dimensional