Skip to main content
Journal cover image

Accuracy of segmentation of a commercial computer-aided detection system for mammography.

Publication ,  Journal Article
Baker, JA; Rosen, EL; Crockett, MM; Lo, JY
Published in: Radiology
May 2005

PURPOSE: To assess the accuracy of segmentation in a commercially available computer-aided detection (CAD) system. MATERIALS AND METHODS: Approval for this study was obtained from the authors' institutional review board. Informed consent was not required by the board for this review, as data were stripped of patient identifiers. Two thousand twenty mammograms from 507 women were analyzed with the hardware and software of a commercial CAD system. The accuracy of the segmentation process was determined semiquantitatively and categorized as near perfect if the skin line of the breast was accurately detected, acceptable if only subcutaneous fat was excluded, or unacceptable if any breast parenchyma was excluded from consideration. The accuracy of segmentation was compared for different breast densities and film sizes by using logistic regression (P < .05). RESULTS: Overall, segmentation was near perfect or acceptable in almost 96.8% of images. However, segmentation defects were significantly more common in mammograms with heterogeneously dense breast tissue (8% unacceptable) than in those with fatty replaced (0% unacceptable), scattered (1.2% unacceptable), or extremely dense (1.8% unacceptable) breast parenchyma (P < .05). For images with unacceptable segmentation, the average percentage of breast parenchyma excluded was almost 25% (range, 5%-100%), with no significant differences among breast densities. CONCLUSION: For one commercial CAD system, segmentation was usually near perfect or acceptable but was unacceptable more than five times more frequently for mammograms of breasts with heterogeneously dense parenchyma than for those with all other breast densities. On average, one-quarter of the breast parenchyma was excluded from CAD analysis for images with unacceptable segmentation.

Duke Scholars

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

May 2005

Volume

235

Issue

2

Start / End Page

385 / 390

Location

United States

Related Subject Headings

  • Technology Assessment, Biomedical
  • Sensitivity and Specificity
  • Prospective Studies
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Neoplasms, Second Primary
  • Middle Aged
  • Mass Screening
  • Mammography
  • Logistic Models
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Baker, J. A., Rosen, E. L., Crockett, M. M., & Lo, J. Y. (2005). Accuracy of segmentation of a commercial computer-aided detection system for mammography. Radiology, 235(2), 385–390. https://doi.org/10.1148/radiol.2352040899
Baker, Jay A., Eric L. Rosen, Michele M. Crockett, and Joseph Y. Lo. “Accuracy of segmentation of a commercial computer-aided detection system for mammography.Radiology 235, no. 2 (May 2005): 385–90. https://doi.org/10.1148/radiol.2352040899.
Baker JA, Rosen EL, Crockett MM, Lo JY. Accuracy of segmentation of a commercial computer-aided detection system for mammography. Radiology. 2005 May;235(2):385–90.
Baker, Jay A., et al. “Accuracy of segmentation of a commercial computer-aided detection system for mammography.Radiology, vol. 235, no. 2, May 2005, pp. 385–90. Pubmed, doi:10.1148/radiol.2352040899.
Baker JA, Rosen EL, Crockett MM, Lo JY. Accuracy of segmentation of a commercial computer-aided detection system for mammography. Radiology. 2005 May;235(2):385–390.
Journal cover image

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

May 2005

Volume

235

Issue

2

Start / End Page

385 / 390

Location

United States

Related Subject Headings

  • Technology Assessment, Biomedical
  • Sensitivity and Specificity
  • Prospective Studies
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Neoplasms, Second Primary
  • Middle Aged
  • Mass Screening
  • Mammography
  • Logistic Models