Comparison between monopolar and tripolar configurations in chronically implanted nerve cuff electrodes
Publication
, Journal Article
Tarler, M; Grill, WM; Mortimer, JT
Published in: Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
December 1, 1995
Nerve cuff electrodes have been shown safe and able to activate selectively specific fascicles in a nerve trunk. Selectivity has been shown using a cuff with four radially placed tripoles thus requiring twelve contacts and twelve lead wires. This study evaluates a simplified cuff electrode, consisting of four radially placed monopole electrodes, requiring only four lead wires, and compares the results to the tripolar electrode configuration. Experiments were performed on two cats, each with an electrode that was implanted for over six months. Results from a correlation analysis and a torque vector likeness measure indicated that the recruitment characteristics of the two configurations were similar in 6 of 8 cases.
Duke Scholars
Published In
Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
ISSN
0589-1019
Publication Date
December 1, 1995
Volume
17
Issue
2
Start / End Page
1093 / 1094
Citation
APA
Chicago
ICMJE
MLA
NLM
Tarler, M., Grill, W. M., & Mortimer, J. T. (1995). Comparison between monopolar and tripolar configurations in chronically implanted nerve cuff electrodes. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings, 17(2), 1093–1094.
Tarler, M., W. M. Grill, and J. T. Mortimer. “Comparison between monopolar and tripolar configurations in chronically implanted nerve cuff electrodes.” Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings 17, no. 2 (December 1, 1995): 1093–94.
Tarler M, Grill WM, Mortimer JT. Comparison between monopolar and tripolar configurations in chronically implanted nerve cuff electrodes. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 1995 Dec 1;17(2):1093–4.
Tarler, M., et al. “Comparison between monopolar and tripolar configurations in chronically implanted nerve cuff electrodes.” Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings, vol. 17, no. 2, Dec. 1995, pp. 1093–94.
Tarler M, Grill WM, Mortimer JT. Comparison between monopolar and tripolar configurations in chronically implanted nerve cuff electrodes. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 1995 Dec 1;17(2):1093–1094.
Published In
Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
ISSN
0589-1019
Publication Date
December 1, 1995
Volume
17
Issue
2
Start / End Page
1093 / 1094