Nerve cuff electrodes have been shown safe and able to activate selectively specific fascicles in a nerve trunk. Selectivity has been shown using a cuff with four radially placed tripoles thus requiring twelve contacts and twelve lead wires. This study evaluates a simplified cuff electrode, consisting of four radially placed monopole electrodes, requiring only four lead wires, and compares the results to the tripolar electrode configuration. Experiments were performed on two cats, each with an electrode that was implanted for over six months. Results from a correlation analysis and a torque vector likeness measure indicated that the recruitment characteristics of the two configurations were similar in 6 of 8 cases.

Duke Scholars

Published In

Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

ISSN

0589-1019

Publication Date

December 1, 1995

Volume

17

Issue

2

Start / End Page

1093 / 1094
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tarler, M., Grill, W. M., & Mortimer, J. T. (1995). Comparison between monopolar and tripolar configurations in chronically implanted nerve cuff electrodes. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings, 17(2), 1093–1094.
Tarler, M., W. M. Grill, and J. T. Mortimer. “Comparison between monopolar and tripolar configurations in chronically implanted nerve cuff electrodes.” Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings 17, no. 2 (December 1, 1995): 1093–94.
Tarler M, Grill WM, Mortimer JT. Comparison between monopolar and tripolar configurations in chronically implanted nerve cuff electrodes. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 1995 Dec 1;17(2):1093–4.
Tarler, M., et al. “Comparison between monopolar and tripolar configurations in chronically implanted nerve cuff electrodes.” Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings, vol. 17, no. 2, Dec. 1995, pp. 1093–94.
Tarler M, Grill WM, Mortimer JT. Comparison between monopolar and tripolar configurations in chronically implanted nerve cuff electrodes. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 1995 Dec 1;17(2):1093–1094.

Published In

Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

ISSN

0589-1019

Publication Date

December 1, 1995

Volume

17

Issue

2

Start / End Page

1093 / 1094