Skip to main content

The development of a population of 4D pediatric XCAT phantoms for CT imaging research and optimization

Publication ,  Journal Article
Norris, H; Zhang, Y; Frush, J; Sturgeon, GM; Minhas, A; Tward, DJ; Ratnanather, JT; Miller, MI; Frush, D; Samei, E; Segars, WP
Published in: Progress in Biomedical Optics and Imaging - Proceedings of SPIE
January 1, 2014

With The increased use of CT examinations, The associated radiation dose has become a large concern, especially for pediatrics. Much research has focused on reducing radiation dose Through new scanning and reconstruction methods. Computational phantoms provide an effective and efficient means for evaluating image quality, patient-specific dose, and organ-specific dose in CT. We previously developed a set of highly-detailed 4D reference pediatric XCAT phantoms at ages of newborn, 1, 5, 10, and 15 years with organ and Tissues masses matched To ICRP Publication 89 values. We now extend This reference set To a series of 64 pediatric phantoms of a variety of ages and height and weight percentiles, representative of The public at large. High resolution PET-CT data was reviewed by a practicing experienced radiologist for anatomic regularity and was Then segmented with manual and semi-Automatic methods To form a Target model. A Multi-Channel Large Deformation Diffeomorphic Metric Mapping (MC-LDDMM) algorithm was used To calculate The Transform from The best age matching pediatric reference phantom To The patient Target. The Transform was used To complete The Target, filling in The non-segmented structures and defining models for The cardiac and respiratory motions. The complete phantoms, consisting of Thousands of structures, were Then manually inspected for anatomical accuracy. 3D CT data was simulated from The phantoms To demonstrate Their ability To generate realistic, patient quality imaging data. The population of pediatric phantoms developed in This work provides a vital Tool To investigate dose reduction Techniques in 3D and 4D pediatric CT. © 2014 SPIE.

Duke Scholars

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

January 1, 2014

Volume

9033
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Norris, H., Zhang, Y., Frush, J., Sturgeon, G. M., Minhas, A., Tward, D. J., … Segars, W. P. (2014). The development of a population of 4D pediatric XCAT phantoms for CT imaging research and optimization. Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 9033. https://doi.org/10.1117/12.2043777
Norris, H., Y. Zhang, J. Frush, G. M. Sturgeon, A. Minhas, D. J. Tward, J. T. Ratnanather, et al. “The development of a population of 4D pediatric XCAT phantoms for CT imaging research and optimization.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE 9033 (January 1, 2014). https://doi.org/10.1117/12.2043777.
Norris H, Zhang Y, Frush J, Sturgeon GM, Minhas A, Tward DJ, et al. The development of a population of 4D pediatric XCAT phantoms for CT imaging research and optimization. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2014 Jan 1;9033.
Norris, H., et al. “The development of a population of 4D pediatric XCAT phantoms for CT imaging research and optimization.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 9033, Jan. 2014. Scopus, doi:10.1117/12.2043777.
Norris H, Zhang Y, Frush J, Sturgeon GM, Minhas A, Tward DJ, Ratnanather JT, Miller MI, Frush D, Samei E, Segars WP. The development of a population of 4D pediatric XCAT phantoms for CT imaging research and optimization. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2014 Jan 1;9033.

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

January 1, 2014

Volume

9033