Fiber-optic detector for real time dosimetry of a micro-planar x-ray beam.

Publication ,  Journal Article
Belley, MD; Stanton, IN; Hadsell, M; Ger, R; Langloss, BW; Lu, J; Zhou, O; Chang, SX; Therien, MJ; Yoshizumi, TT
Published in: Medical physics
April 2015

Here, the authors describe a dosimetry measurement technique for microbeam radiation therapy using a nanoparticle-terminated fiber-optic dosimeter (nano-FOD).The nano-FOD was placed in the center of a 2 cm diameter mouse phantom to measure the deep tissue dose and lateral beam profile of a planar x-ray microbeam.The continuous dose rate at the x-ray microbeam peak measured with the nano-FOD was 1.91 ± 0.06 cGy s(-1), a value 2.7% higher than that determined via radiochromic film measurements (1.86 ± 0.15 cGy s(-1)). The nano-FOD-determined lateral beam full-width half max value of 420 μm exceeded that measured using radiochromic film (320 μm). Due to the 8° angle of the collimated microbeam and resulting volumetric effects within the scintillator, the profile measurements reported here are estimated to achieve a resolution of ∼0.1 mm; however, for a beam angle of 0°, the theoretical resolution would approach the thickness of the scintillator (∼0.01 mm).This work provides proof-of-concept data and demonstrates that the novel nano-FOD device can be used to perform real-time dosimetry in microbeam radiation therapy to measure the continuous dose rate at the x-ray microbeam peak as well as the lateral beam shape.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Medical physics

DOI

EISSN

2473-4209

ISSN

0094-2405

Publication Date

April 2015

Volume

42

Issue

4

Start / End Page

1966 / 1972

Related Subject Headings

  • X-Rays
  • X-Ray Therapy
  • Radiotherapy
  • Radiometry
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Nanoparticles
  • Microscopy, Electron, Scanning
  • Mice
  • Fiber Optic Technology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Belley, M. D., Stanton, I. N., Hadsell, M., Ger, R., Langloss, B. W., Lu, J., … Yoshizumi, T. T. (2015). Fiber-optic detector for real time dosimetry of a micro-planar x-ray beam. Medical Physics, 42(4), 1966–1972. https://doi.org/10.1118/1.4915078
Belley, Matthew D., Ian N. Stanton, Mike Hadsell, Rachel Ger, Brian W. Langloss, Jianping Lu, Otto Zhou, Sha X. Chang, Michael J. Therien, and Terry T. Yoshizumi. “Fiber-optic detector for real time dosimetry of a micro-planar x-ray beam.Medical Physics 42, no. 4 (April 2015): 1966–72. https://doi.org/10.1118/1.4915078.
Belley MD, Stanton IN, Hadsell M, Ger R, Langloss BW, Lu J, et al. Fiber-optic detector for real time dosimetry of a micro-planar x-ray beam. Medical physics. 2015 Apr;42(4):1966–72.
Belley, Matthew D., et al. “Fiber-optic detector for real time dosimetry of a micro-planar x-ray beam.Medical Physics, vol. 42, no. 4, Apr. 2015, pp. 1966–72. Epmc, doi:10.1118/1.4915078.
Belley MD, Stanton IN, Hadsell M, Ger R, Langloss BW, Lu J, Zhou O, Chang SX, Therien MJ, Yoshizumi TT. Fiber-optic detector for real time dosimetry of a micro-planar x-ray beam. Medical physics. 2015 Apr;42(4):1966–1972.

Published In

Medical physics

DOI

EISSN

2473-4209

ISSN

0094-2405

Publication Date

April 2015

Volume

42

Issue

4

Start / End Page

1966 / 1972

Related Subject Headings

  • X-Rays
  • X-Ray Therapy
  • Radiotherapy
  • Radiometry
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Nanoparticles
  • Microscopy, Electron, Scanning
  • Mice
  • Fiber Optic Technology