Journal articles  - Journal Article
Stanhope, C; Wu, QJ; Yuan, L; Liu, J; Hood, R; Yin, F-F; Adamson, J
Published in: Phys Med Biol
June 21, 2015

Increased interest regarding sensitivity of pre-treatment intensity modulated radiotherapy and volumetric modulated arc radiotherapy (VMAT) quality assurance (QA) to delivery errors has led to the development of dose-volume histogram (DVH) based analysis. This paradigm shift necessitates a change in the acceptance criteria and action tolerance for QA. Here we present a knowledge based technique to objectively quantify degradations in DVH for prostate radiotherapy. Using machine learning, organ-at-risk (OAR) DVHs from a population of 198 prior patients' plans were adapted to a test patient's anatomy to establish patient-specific DVH ranges. This technique was applied to single arc prostate VMAT plans to evaluate various simulated delivery errors: systematic single leaf offsets, systematic leaf bank offsets, random normally distributed leaf fluctuations, systematic lag in gantry angle of the mutli-leaf collimators (MLCs), fluctuations in dose rate, and delivery of each VMAT arc with a constant rather than variable dose rate.Quantitative Analyses of Normal Tissue Effects in the Clinic suggests V75Gy dose limits of 15% for the rectum and 25% for the bladder, however the knowledge based constraints were more stringent: 8.48 ± 2.65% for the rectum and 4.90 ± 1.98% for the bladder. 19 ± 10 mm single leaf and 1.9 ± 0.7 mm single bank offsets resulted in rectum DVHs worse than 97.7% (2σ) of clinically accepted plans. PTV degradations fell outside of the acceptable range for 0.6 ± 0.3 mm leaf offsets, 0.11 ± 0.06 mm bank offsets, 0.6 ± 1.3 mm of random noise, and 1.0 ± 0.7° of gantry-MLC lag.Utilizing a training set comprised of prior treatment plans, machine learning is used to predict a range of achievable DVHs for the test patient's anatomy. Consequently, degradations leading to statistical outliers may be identified. A knowledge based QA evaluation enables customized QA criteria per treatment site, institution and/or physician and can often be more sensitive to errors than criteria based on organ complication rates.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Phys Med Biol

DOI

EISSN

1361-6560

Publication Date

June 21, 2015

Volume

60

Issue

12

Start / End Page

4873 / 4891

Location

England

Related Subject Headings

  • Radiotherapy, Intensity-Modulated
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Quality Control
  • Quality Assurance, Health Care
  • Prostatic Neoplasms
  • Nuclear Medicine & Medical Imaging
  • Male
  • Humans
  • Algorithms
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Stanhope, C., Wu, Q. J., Yuan, L., Liu, J., Hood, R., Yin, F.-F., & Adamson, J. (2015). Utilizing knowledge from prior plans in the evaluation of quality assurance. Phys Med Biol, 60(12), 4873–4891. https://doi.org/10.1088/0031-9155/60/12/4873
Stanhope, Carl, Q Jackie Wu, Lulin Yuan, Jianfei Liu, Rodney Hood, Fang-Fang Yin, and Justus Adamson. “Utilizing knowledge from prior plans in the evaluation of quality assurance.Phys Med Biol 60, no. 12 (June 21, 2015): 4873–91. https://doi.org/10.1088/0031-9155/60/12/4873.
Stanhope C, Wu QJ, Yuan L, Liu J, Hood R, Yin F-F, et al. Utilizing knowledge from prior plans in the evaluation of quality assurance. Phys Med Biol. 2015 Jun 21;60(12):4873–91.
Stanhope, Carl, et al. “Utilizing knowledge from prior plans in the evaluation of quality assurance.Phys Med Biol, vol. 60, no. 12, June 2015, pp. 4873–91. Pubmed, doi:10.1088/0031-9155/60/12/4873.
Stanhope C, Wu QJ, Yuan L, Liu J, Hood R, Yin F-F, Adamson J. Utilizing knowledge from prior plans in the evaluation of quality assurance. Phys Med Biol. 2015 Jun 21;60(12):4873–4891.
Journal cover image

Published In

Phys Med Biol

DOI

EISSN

1361-6560

Publication Date

June 21, 2015

Volume

60

Issue

12

Start / End Page

4873 / 4891

Location

England

Related Subject Headings

  • Radiotherapy, Intensity-Modulated
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Quality Control
  • Quality Assurance, Health Care
  • Prostatic Neoplasms
  • Nuclear Medicine & Medical Imaging
  • Male
  • Humans
  • Algorithms