High-Pitch Dual-Source MDCT for Imaging of the Thoracoabdominal Aorta: Relationships Among Radiation Dose, Noise, Pitch, and Body Size in a Phantom Experiment and Clinical Study.

Publication ,  Journal Article
Mileto, A; Ramirez-Giraldo, JC; Nelson, RC; Hurwitz, LM; Choudhury, KR; Seaman, DM; Marin, D
Published in: AJR Am J Roentgenol
October 2015

OBJECTIVE: The purpose of this study was to investigate, both in a phantom experiment and a within-patient clinical study the relationships among radiation dose, image noise, pitch, and body size in MDCT angiography of the thoracoabdominal aorta, with the use of high-pitch dual-source and standard-pitch single-source acquisitions. MATERIALS AND METHODS: A proprietary tapered phantom consisting of four ultrahigh-molecular-weight polyethylene cylinders was used to mimic the body size ranges (small, medium, large, and extra large) of patients in the United States. The phantom was imaged using both standard-pitch (0.8) and various high-pitch (range, 2.0-3.2 [in increments of 0.4]) settings. Standard-pitch and high-pitch acquisitions were also performed in 45 patients (27 men, 18 women; mean age, 67.6 years). RESULTS: At standard pitch, the volume CT dose index (CTDIvol) increased with phantom size, in a logistic sigmoid relationship. At high-pitch settings, the CTDIvol increased gradually in relation to phantom size, up to a threshold (denoted by tCTDI[pitch] ≈ 48.3-7.5 pitch), which linearly decreased (R(2) = 0.99) with pitch (maximum CTDIvol output at pitch [maxCTDI(pitch)] ≈ 18.9-3.9 pitch). A linear decrease in the size-specific dose estimate (SSDE) was observed beyond phantom size thresholds (tSSDE[pitch] ≈ 47.6-8.6 pitch) linearly decreasing (R(2) = 0.98) with pitch (maximum SSDE output at pitch [maxSSDE(pitch)] ≈ 15.5-1.3 pitch). Image noise was statistically significantly lower at standard pitch than at high-pitch settings (p = 0.01). In patients, statistically significant differences were noted between standard and high-pitch settings in the mean CTDIvol(10.8 ± 2.6 and 8.3 ± 0.7 mGy, respectively), SSDE (11.3 ± 2.1 and 8.8 ± 1.5 mGy, respectively), and noise (9.7 ± 2.2 and 14 ± 4.2, respectively) (p < .0001, for all comparisons). CONCLUSION: Lower radiation dose levels achieved with the use of a high-pitch technique reflect limitations in tube output occurring for medium to large body sizes, with an associated exponential increase in noise. The standard- and high-pitch techniques yield similar radiation dose levels for small body sizes.

Duke Scholars

Published In

AJR Am J Roentgenol

DOI

EISSN

1546-3141

Publication Date

October 2015

Volume

205

Issue

4

Start / End Page

834 / 839

Location

United States

Related Subject Headings

  • Retrospective Studies
  • Radiation Dosage
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Multidetector Computed Tomography
  • Male
  • Humans
  • Female
  • Body Size
  • Aortography
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Mileto, A., Ramirez-Giraldo, J. C., Nelson, R. C., Hurwitz, L. M., Choudhury, K. R., Seaman, D. M., & Marin, D. (2015). High-Pitch Dual-Source MDCT for Imaging of the Thoracoabdominal Aorta: Relationships Among Radiation Dose, Noise, Pitch, and Body Size in a Phantom Experiment and Clinical Study. AJR Am J Roentgenol, 205(4), 834–839. https://doi.org/10.2214/AJR.15.14334
Mileto, Achille, Juan Carlos Ramirez-Giraldo, Rendon C. Nelson, Lynne M. Hurwitz, Kingshuk Roy Choudhury, Danielle M. Seaman, and Daniele Marin. “High-Pitch Dual-Source MDCT for Imaging of the Thoracoabdominal Aorta: Relationships Among Radiation Dose, Noise, Pitch, and Body Size in a Phantom Experiment and Clinical Study.AJR Am J Roentgenol 205, no. 4 (October 2015): 834–39. https://doi.org/10.2214/AJR.15.14334.
Mileto A, Ramirez-Giraldo JC, Nelson RC, Hurwitz LM, Choudhury KR, Seaman DM, et al. High-Pitch Dual-Source MDCT for Imaging of the Thoracoabdominal Aorta: Relationships Among Radiation Dose, Noise, Pitch, and Body Size in a Phantom Experiment and Clinical Study. AJR Am J Roentgenol. 2015 Oct;205(4):834–9.
Mileto, Achille, et al. “High-Pitch Dual-Source MDCT for Imaging of the Thoracoabdominal Aorta: Relationships Among Radiation Dose, Noise, Pitch, and Body Size in a Phantom Experiment and Clinical Study.AJR Am J Roentgenol, vol. 205, no. 4, Oct. 2015, pp. 834–39. Pubmed, doi:10.2214/AJR.15.14334.
Mileto A, Ramirez-Giraldo JC, Nelson RC, Hurwitz LM, Choudhury KR, Seaman DM, Marin D. High-Pitch Dual-Source MDCT for Imaging of the Thoracoabdominal Aorta: Relationships Among Radiation Dose, Noise, Pitch, and Body Size in a Phantom Experiment and Clinical Study. AJR Am J Roentgenol. 2015 Oct;205(4):834–839.

Published In

AJR Am J Roentgenol

DOI

EISSN

1546-3141

Publication Date

October 2015

Volume

205

Issue

4

Start / End Page

834 / 839

Location

United States

Related Subject Headings

  • Retrospective Studies
  • Radiation Dosage
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Multidetector Computed Tomography
  • Male
  • Humans
  • Female
  • Body Size
  • Aortography