Skip to main content
Journal cover image

Evaluation of microarray surfaces and arraying parameters for autoantibody profiling.

Publication ,  Journal Article
Balboni, I; Limb, C; Tenenbaum, JD; Utz, PJ
Published in: Proteomics
September 2008

Autoantigen microarrays are being used increasingly to study autoimmunity. Significant variation has been observed when comparing microarray surfaces, printing methods, and probing conditions. In the present study, 24 surfaces and several arraying parameters were analyzed using >500 feature autoantigen microarrays printed with quill pins. A small subset of slides, including FAST, PATH, and SuperEpoxy2, performed well while maintaining the sensitivity and specificity of autoantigen microarrays previously demonstrated by our laboratory. By optimizing the major variables in our autoantigen microarray platform, subtle differences in serum samples can be identified that will shed light on disease pathogenesis.

Duke Scholars

Published In

Proteomics

DOI

EISSN

1615-9861

Publication Date

September 2008

Volume

8

Issue

17

Start / End Page

3443 / 3449

Location

Germany

Related Subject Headings

  • Protein Array Analysis
  • Humans
  • Biochemistry & Molecular Biology
  • Autoimmune Diseases
  • Autoantigens
  • Autoantibodies
  • Animals
  • 32 Biomedical and clinical sciences
  • 31 Biological sciences
  • 11 Medical and Health Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Balboni, I., Limb, C., Tenenbaum, J. D., & Utz, P. J. (2008). Evaluation of microarray surfaces and arraying parameters for autoantibody profiling. Proteomics, 8(17), 3443–3449. https://doi.org/10.1002/pmic.200800146
Balboni, Imelda, Cindy Limb, Jessica D. Tenenbaum, and Paul J. Utz. “Evaluation of microarray surfaces and arraying parameters for autoantibody profiling.Proteomics 8, no. 17 (September 2008): 3443–49. https://doi.org/10.1002/pmic.200800146.
Balboni I, Limb C, Tenenbaum JD, Utz PJ. Evaluation of microarray surfaces and arraying parameters for autoantibody profiling. Proteomics. 2008 Sep;8(17):3443–9.
Balboni, Imelda, et al. “Evaluation of microarray surfaces and arraying parameters for autoantibody profiling.Proteomics, vol. 8, no. 17, Sept. 2008, pp. 3443–49. Pubmed, doi:10.1002/pmic.200800146.
Balboni I, Limb C, Tenenbaum JD, Utz PJ. Evaluation of microarray surfaces and arraying parameters for autoantibody profiling. Proteomics. 2008 Sep;8(17):3443–3449.
Journal cover image

Published In

Proteomics

DOI

EISSN

1615-9861

Publication Date

September 2008

Volume

8

Issue

17

Start / End Page

3443 / 3449

Location

Germany

Related Subject Headings

  • Protein Array Analysis
  • Humans
  • Biochemistry & Molecular Biology
  • Autoimmune Diseases
  • Autoantigens
  • Autoantibodies
  • Animals
  • 32 Biomedical and clinical sciences
  • 31 Biological sciences
  • 11 Medical and Health Sciences