Skip to main content

Use of Peptide-Based Enzyme-Linked Immunosorbent Assay followed by Immunofluorescence Assay To Document Ehrlichia chaffeensis as a Cause of Febrile Illness in Nicaragua.

Publication ,  Journal Article
Chikeka, I; Matute, AJ; Dumler, JS; Woods, CW; Mayorga, O; Reller, ME
Published in: J Clin Microbiol
June 2016

Ehrlichia chaffeensis, the etiologic agent of human monocytic ehrlichiosis (HME), has been extensively studied as a cause of acute febrile illness and an emerging tick-borne zoonosis in the United States. Limited data suggest its presence in other regions, including Central and South America but not Nicaragua to date. Diagnosis of E. chaffeensis infection by indirect immunofluorescence assay (IFA) is the reference standard due to its presumed high sensitivity and specificity, but IFA is impractical, variably reproducible, and cumbersome for large epidemiologic studies and for clinical diagnosis in resource-poor regions. We evaluated a high-throughput, objective peptide-based enzyme-linked immunosorbent assay (ELISA) for use alone or in combination with IFA. We found that it performed best as a screening test (sensitivity, 100%; specificity, 84%) to reduce the proportion of serum samples that were required by the more cumbersome and subjective IFA testing to <20%. Using a two-step diagnostic approach (IFA is performed if the ELISA is positive), we identified E. chaffeensis or a serologically and antigenically similar organism as a heretofore unrecognized cause of acute febrile illness in humans in Nicaragua and demonstrated the utility of the peptide ELISA as a screening tool for large-scale clinical studies.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Clin Microbiol

DOI

EISSN

1098-660X

Publication Date

June 2016

Volume

54

Issue

6

Start / End Page

1581 / 1585

Location

United States

Related Subject Headings

  • Young Adult
  • Tick-Borne Diseases
  • Sensitivity and Specificity
  • Nicaragua
  • Middle Aged
  • Microbiology
  • Male
  • Infant
  • Humans
  • Fluorescent Antibody Technique, Indirect
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chikeka, I., Matute, A. J., Dumler, J. S., Woods, C. W., Mayorga, O., & Reller, M. E. (2016). Use of Peptide-Based Enzyme-Linked Immunosorbent Assay followed by Immunofluorescence Assay To Document Ehrlichia chaffeensis as a Cause of Febrile Illness in Nicaragua. J Clin Microbiol, 54(6), 1581–1585. https://doi.org/10.1128/JCM.03331-15
Chikeka, Ijeuru, Armando J. Matute, J Stephen Dumler, Christopher W. Woods, Orlando Mayorga, and Megan E. Reller. “Use of Peptide-Based Enzyme-Linked Immunosorbent Assay followed by Immunofluorescence Assay To Document Ehrlichia chaffeensis as a Cause of Febrile Illness in Nicaragua.J Clin Microbiol 54, no. 6 (June 2016): 1581–85. https://doi.org/10.1128/JCM.03331-15.
Chikeka, Ijeuru, et al. “Use of Peptide-Based Enzyme-Linked Immunosorbent Assay followed by Immunofluorescence Assay To Document Ehrlichia chaffeensis as a Cause of Febrile Illness in Nicaragua.J Clin Microbiol, vol. 54, no. 6, June 2016, pp. 1581–85. Pubmed, doi:10.1128/JCM.03331-15.

Published In

J Clin Microbiol

DOI

EISSN

1098-660X

Publication Date

June 2016

Volume

54

Issue

6

Start / End Page

1581 / 1585

Location

United States

Related Subject Headings

  • Young Adult
  • Tick-Borne Diseases
  • Sensitivity and Specificity
  • Nicaragua
  • Middle Aged
  • Microbiology
  • Male
  • Infant
  • Humans
  • Fluorescent Antibody Technique, Indirect