Intraoperative Monitoring of Pulmonary Artery Physiology With Transesophageal Echocardiography in a Patient With an Extensive Pulmonary Aneurysm Undergoing Partial Nephrectomy.
Publication
, Journal Article
Plakke, MJ; Maxwell, CD; Bottiger, BA
Published in: A A Case Rep
September 1, 2016
Surgical patients with pulmonary hypertension present a significant challenge to the anesthesiologist. Continuous perioperative monitoring of pulmonary artery (PA) pressure is recommended and most often accomplished with a PA catheter. Placement of a PA catheter may be difficult or contraindicated, and in these cases, transesophageal echocardiography is a useful alternative to monitor dynamic PA physiology. In this case, we used intraoperative transesophageal echocardiography to detect changes in peak PA pressure and guide clinical treatment in a patient with pulmonary hypertension and an extensive PA aneurysm undergoing partial nephrectomy.
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
A A Case Rep
DOI
EISSN
2325-7237
Publication Date
September 1, 2016
Volume
7
Issue
5
Start / End Page
108 / 111
Location
United States
Related Subject Headings
- Pulmonary Artery
- Nephrectomy
- Monitoring, Intraoperative
- Middle Aged
- Humans
- Female
- Echocardiography, Transesophageal
- Aneurysm
Citation
APA
Chicago
ICMJE
MLA
NLM
Plakke, M. J., Maxwell, C. D., & Bottiger, B. A. (2016). Intraoperative Monitoring of Pulmonary Artery Physiology With Transesophageal Echocardiography in a Patient With an Extensive Pulmonary Aneurysm Undergoing Partial Nephrectomy. A A Case Rep, 7(5), 108–111. https://doi.org/10.1213/XAA.0000000000000359
Plakke, Michael J., Cory D. Maxwell, and Brandi A. Bottiger. “Intraoperative Monitoring of Pulmonary Artery Physiology With Transesophageal Echocardiography in a Patient With an Extensive Pulmonary Aneurysm Undergoing Partial Nephrectomy.” A A Case Rep 7, no. 5 (September 1, 2016): 108–11. https://doi.org/10.1213/XAA.0000000000000359.
Plakke MJ, Maxwell CD, Bottiger BA. Intraoperative Monitoring of Pulmonary Artery Physiology With Transesophageal Echocardiography in a Patient With an Extensive Pulmonary Aneurysm Undergoing Partial Nephrectomy. A A Case Rep. 2016 Sep 1;7(5):108–11.
Plakke, Michael J., et al. “Intraoperative Monitoring of Pulmonary Artery Physiology With Transesophageal Echocardiography in a Patient With an Extensive Pulmonary Aneurysm Undergoing Partial Nephrectomy.” A A Case Rep, vol. 7, no. 5, Sept. 2016, pp. 108–11. Pubmed, doi:10.1213/XAA.0000000000000359.
Plakke MJ, Maxwell CD, Bottiger BA. Intraoperative Monitoring of Pulmonary Artery Physiology With Transesophageal Echocardiography in a Patient With an Extensive Pulmonary Aneurysm Undergoing Partial Nephrectomy. A A Case Rep. 2016 Sep 1;7(5):108–111.
Published In
A A Case Rep
DOI
EISSN
2325-7237
Publication Date
September 1, 2016
Volume
7
Issue
5
Start / End Page
108 / 111
Location
United States
Related Subject Headings
- Pulmonary Artery
- Nephrectomy
- Monitoring, Intraoperative
- Middle Aged
- Humans
- Female
- Echocardiography, Transesophageal