Skip to main content
Journal cover image

Fast measurement of blood T1 in the human jugular vein at 3 Tesla.

Publication ,  Journal Article
Qin, Q; Strouse, JJ; van Zijl, PCM
Published in: Magn Reson Med
May 2011

Current T(1) values for blood at 3T largely came from in vitro studies on animal blood or freshly drawn human blood. Measurement of blood T(1) in vivo could provide more specific information, e.g., for individuals with abnormal blood composition. Here, blood T(1) at 3T was measured rapidly (<1 min) in the internal jugular vein using a fast inversion-recovery technique in which multiple inversion time can be acquired rapidly due to constant refreshing of blood. Multishot EPI acquisition with flow compensation yielded high resolution images with minimum partial volume effect. Results showed T(1) = 1852 ± 104 msec among 24 healthy adults, a value higher than for bovine blood phantoms (1584 msec at Hct of 42%). A second finding was that of a significant difference (P < 0.01) between men and women, namely T(1) = 1780 ± 89 msec (n = 12) and T(1) = 1924 ± 58 msec (n = 12), respectively. This difference in normal subjects is tentatively explained by the difference in Hct between genders. Interestingly, however, studies done on sickle cell anemia patients with much lower Hct (23 ± 3%, n = 10) revealed similar venous blood T(1) = 1924 ± 82 msec, indicating other possible physical influences affecting blood T(1).

Duke Scholars

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

May 2011

Volume

65

Issue

5

Start / End Page

1297 / 1304

Location

United States

Related Subject Headings

  • Oxygen
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Magnetic Resonance Angiography
  • Jugular Veins
  • Image Interpretation, Computer-Assisted
  • Humans
  • Female
  • Child
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Qin, Q., Strouse, J. J., & van Zijl, P. C. M. (2011). Fast measurement of blood T1 in the human jugular vein at 3 Tesla. Magn Reson Med, 65(5), 1297–1304. https://doi.org/10.1002/mrm.22723
Qin, Qin, John J. Strouse, and Peter C. M. van Zijl. “Fast measurement of blood T1 in the human jugular vein at 3 Tesla.Magn Reson Med 65, no. 5 (May 2011): 1297–1304. https://doi.org/10.1002/mrm.22723.
Qin Q, Strouse JJ, van Zijl PCM. Fast measurement of blood T1 in the human jugular vein at 3 Tesla. Magn Reson Med. 2011 May;65(5):1297–304.
Qin, Qin, et al. “Fast measurement of blood T1 in the human jugular vein at 3 Tesla.Magn Reson Med, vol. 65, no. 5, May 2011, pp. 1297–304. Pubmed, doi:10.1002/mrm.22723.
Qin Q, Strouse JJ, van Zijl PCM. Fast measurement of blood T1 in the human jugular vein at 3 Tesla. Magn Reson Med. 2011 May;65(5):1297–1304.
Journal cover image

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

May 2011

Volume

65

Issue

5

Start / End Page

1297 / 1304

Location

United States

Related Subject Headings

  • Oxygen
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Magnetic Resonance Angiography
  • Jugular Veins
  • Image Interpretation, Computer-Assisted
  • Humans
  • Female
  • Child