OBJECTIVES: This study sought to evaluate this transcatheter aortic valve (TAV) bioprosthesis in patients who are poorly suitable for surgical aortic valve (AV) replacement. BACKGROUND: A novel self-expandable TAV bioprosthesis was designed to provide a low-profile delivery system, conformable annular sealing, and the ability to resheath and reposition during deployment. METHODS: The Evolut R U.S. study included 241 patients with severe aortic stenosis who were deemed to be at least high risk for surgery treated at 23 clinical sites in the United States. Clinical outcomes at 30 days were evaluated using Valve Academic Research Consortium-2 criteria. An independent echocardiography laboratory was used to evaluate hemodynamic outcomes. RESULTS: Patients were elderly (83.3 ± 7.2 years of age) and had high surgical risk (Society of Thoracic Surgeons predicted risk of mortality of 7.4 ± 3.4%). The majority of patients (89.5%) were treated by iliofemoral access. Resheathing or recapturing was performed in 22.6% of patients; more than 1 valve was required in 3 patients (1.3%). The 30-day outcomes included all-cause mortality (2.5%), disabling stroke (3.3%), major vascular complications (7.5%), life-threatening or disabling bleeding (7.1%), and new permanent pacemaker (16.4%). AV hemodynamics were markedly improved at 30 days: the mean AV gradient was reduced from 48.2 ± 13.0 mm Hg to 7.8 ± 3.1 mm Hg (p < 0.001) and AV area increased from 0.6 ± 0.2 cm2 to 1.9 ± 0.5 cm2 (p < 0.001). Moderate residual paravalvular leak was identified in 5.3% of patients. CONCLUSIONS: We conclude that this novel self-expanding TAV bioprosthesis is safe and effective for the treatment of patients with severe aortic stenosis who are suboptimal for surgery. (Medtronic CoreValve Evolut R U.S. Clinical Study; NCT02207569).

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

JACC Cardiovasc Interv

DOI

EISSN

1876-7605

Publication Date

February 13, 2017

Volume

10

Issue

3

Start / End Page

268 / 275

Location

United States

Related Subject Headings

  • United States
  • Treatment Outcome
  • Transcatheter Aortic Valve Replacement
  • Time Factors
  • Severity of Illness Index
  • Risk Factors
  • Risk Assessment
  • Recovery of Function
  • Prosthesis Design
  • Prospective Studies
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Popma, J. J., Reardon, M. J., Khabbaz, K., Harrison, J. K., Hughes, G. C., Kodali, S., … Williams, M. R. (2017). Early Clinical Outcomes After Transcatheter Aortic Valve Replacement Using a Novel Self-Expanding Bioprosthesis in Patients With Severe Aortic Stenosis Who Are Suboptimal for Surgery: Results of the Evolut R U.S. Study. JACC Cardiovasc Interv, 10(3), 268–275. https://doi.org/10.1016/j.jcin.2016.08.050
Popma, Jeffrey J., Michael J. Reardon, Kamal Khabbaz, J Kevin Harrison, G Chad Hughes, Susheel Kodali, Isaac George, et al. “Early Clinical Outcomes After Transcatheter Aortic Valve Replacement Using a Novel Self-Expanding Bioprosthesis in Patients With Severe Aortic Stenosis Who Are Suboptimal for Surgery: Results of the Evolut R U.S. Study.JACC Cardiovasc Interv 10, no. 3 (February 13, 2017): 268–75. https://doi.org/10.1016/j.jcin.2016.08.050.
Popma JJ, Reardon MJ, Khabbaz K, Harrison JK, Hughes GC, Kodali S, George I, Deeb GM, Chetcuti S, Kipperman R, Brown J, Qiao H, Slater J, Williams MR. Early Clinical Outcomes After Transcatheter Aortic Valve Replacement Using a Novel Self-Expanding Bioprosthesis in Patients With Severe Aortic Stenosis Who Are Suboptimal for Surgery: Results of the Evolut R U.S. Study. JACC Cardiovasc Interv. 2017 Feb 13;10(3):268–275.
Journal cover image

Published In

JACC Cardiovasc Interv

DOI

EISSN

1876-7605

Publication Date

February 13, 2017

Volume

10

Issue

3

Start / End Page

268 / 275

Location

United States

Related Subject Headings

  • United States
  • Treatment Outcome
  • Transcatheter Aortic Valve Replacement
  • Time Factors
  • Severity of Illness Index
  • Risk Factors
  • Risk Assessment
  • Recovery of Function
  • Prosthesis Design
  • Prospective Studies