Skip to main content

SU-E-I-07: Proposal for a Novel Algorithm of Effective Dose Evaluation for Medical Radiation Exposure.

Publication ,  Journal Article
Wang, C; Dewhirst, M; Jiang, X; Qian, Z; Boon, S; Yoshizumi, T
Published in: Med Phys
June 2012

PURPOSE: The validity of effective dose (ED) in medical applications, which mostly involving partial-organ irradiation, has long been argued. We now propose a new algorithm of effective dose evaluation for medical radiation exposure. The new algorithm will include new Relative Volume Factors, or RVFs, to account for the relative irradiated volume of the partially-irradiated organs, such as skin and bone marrow. METHODS: To validate the proposed algorithm, three ED evaluation methods were applied to five neuro-imaging protocols of a C-arm cone-beam CT: 1) MOSFET-anthropomorphic- phantom measurement for organ doses, ED evaluated with the original ICRP algorithm; 2) using the same MOSFET-measured organ doses, ED evaluated with the new algorithm; and 3) Monte Carlo (PCXMC, developed by STUK) dose estimation as gold standard. RESULTS: For all five imaging protocols, the ED evaluations by the new algorithm agreed very well with the Monte Carlo simulation results (within 10% difference), whereas the original ICRP algorithm overestimated EDs by approximately a factor of 2. CONCLUSIONS: The proposed algorithm provides a more accurate estimation of ED in medical exposures than the original ICRP algorithm. It potentially establishes the ED as a more reasonable index for cross-protocol dose comparison.

Duke Scholars

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

June 2012

Volume

39

Issue

6Part4

Start / End Page

3626

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wang, C., Dewhirst, M., Jiang, X., Qian, Z., Boon, S., & Yoshizumi, T. (2012). SU-E-I-07: Proposal for a Novel Algorithm of Effective Dose Evaluation for Medical Radiation Exposure. Med Phys, 39(6Part4), 3626. https://doi.org/10.1118/1.4734721
Wang, C., M. Dewhirst, X. Jiang, Z. Qian, S. Boon, and T. Yoshizumi. “SU-E-I-07: Proposal for a Novel Algorithm of Effective Dose Evaluation for Medical Radiation Exposure.Med Phys 39, no. 6Part4 (June 2012): 3626. https://doi.org/10.1118/1.4734721.
Wang C, Dewhirst M, Jiang X, Qian Z, Boon S, Yoshizumi T. SU-E-I-07: Proposal for a Novel Algorithm of Effective Dose Evaluation for Medical Radiation Exposure. Med Phys. 2012 Jun;39(6Part4):3626.
Wang, C., et al. “SU-E-I-07: Proposal for a Novel Algorithm of Effective Dose Evaluation for Medical Radiation Exposure.Med Phys, vol. 39, no. 6Part4, June 2012, p. 3626. Pubmed, doi:10.1118/1.4734721.
Wang C, Dewhirst M, Jiang X, Qian Z, Boon S, Yoshizumi T. SU-E-I-07: Proposal for a Novel Algorithm of Effective Dose Evaluation for Medical Radiation Exposure. Med Phys. 2012 Jun;39(6Part4):3626.

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

June 2012

Volume

39

Issue

6Part4

Start / End Page

3626

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences