PURPOSE: To evaluate surface doses for beams with and without flattening filter (FF and FFF) in breast cancer treatment plans. Measurements were performed for validation. Delivery:TrueBeam, used in this study, is a linear accelerator newly designed to deliver both flattened and flattening filter free beams. Planning: Eclipse treatment planning system (TPS) is commissioned and utilized. We used 6 MV half beams from FFF mode to plan standard tangential breast treatments due to its similar shape to wedged FF beams. We compare these plans with those from 6MV flattened beams with 30° wedges. Measurement Validation: We used a Rando phantom and InLightTM nanoDots Optically stimulated luminescence dosimetry(OSLD) system to measure surface doses from FFF beams. Medial, apex and lateral locations from central plane, as well as positions from caudal and cranial regions, were included. RESULTS: Planning comparison: surface doses from plans with FFF beams were2.2%-4.7% lower than those with flattened beams with wedges, when doses at deeper depth from central axis stay close in value. Measurement validation: In the apex region of central plane,the OSLD readouts are 4.5% - 6.3% higher than calculated. In the caudal, cranial and medial regions, TPS underestimated the surface dose from 7.2-8.7%. CONCLUSIONS: For standard tangential breast plans, surface doses are lower with FFF beam than with flattened beams with wedges. The surface doses from FFF beams were validated with OSLD measurements, taking into account the uncertainty of the dosimeter and its angular dependence.

Duke Scholars

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

June 2012

Volume

39

Issue

6Part14

Start / End Page

3768 / 3769

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Xie, J., Chen, W., Cui, Y., Giaddui, T., Galvin, J., Yu, Y., & Xiao, Y. (2012). SU-E-T-284: Surface Dose Evaluation for Beams with and without Flattening Filter in Breast Cancer Treatment. Med Phys, 39(6Part14), 3768–3769. https://doi.org/10.1118/1.4735352
Xie, J., W. Chen, Y. Cui, T. Giaddui, J. Galvin, Y. Yu, and Y. Xiao. “SU-E-T-284: Surface Dose Evaluation for Beams with and without Flattening Filter in Breast Cancer Treatment.Med Phys 39, no. 6Part14 (June 2012): 3768–69. https://doi.org/10.1118/1.4735352.
Xie J, Chen W, Cui Y, Giaddui T, Galvin J, Yu Y, et al. SU-E-T-284: Surface Dose Evaluation for Beams with and without Flattening Filter in Breast Cancer Treatment. Med Phys. 2012 Jun;39(6Part14):3768–9.
Xie, J., et al. “SU-E-T-284: Surface Dose Evaluation for Beams with and without Flattening Filter in Breast Cancer Treatment.Med Phys, vol. 39, no. 6Part14, June 2012, pp. 3768–69. Pubmed, doi:10.1118/1.4735352.
Xie J, Chen W, Cui Y, Giaddui T, Galvin J, Yu Y, Xiao Y. SU-E-T-284: Surface Dose Evaluation for Beams with and without Flattening Filter in Breast Cancer Treatment. Med Phys. 2012 Jun;39(6Part14):3768–3769.

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

June 2012

Volume

39

Issue

6Part14

Start / End Page

3768 / 3769

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences