Aortic valve replacement in a diseased bicuspid valve eleven years after transplantation.
Publication
, Journal Article
Joyce, DL; Russell, SD; Conte, JV; Cattaneo, SM
Published in: Interact Cardiovasc Thorac Surg
May 2009
Cardiac allotransplantation is subject to a number of chronic complications that may limit graft survival. These include allograft coronary artery disease, renal dysfunction, hypertension, and malignancy, which are largely due to the immuno-modulatory and adverse effects of transplant medications. Reoperation for native allograft disease progression is a rarer phenomenon. We report a case of aortic valve replacement for bicuspid aortic valve stenosis that occurred in a patient more than ten years after cardiac transplantation.
Duke Scholars
Published In
Interact Cardiovasc Thorac Surg
DOI
EISSN
1569-9285
Publication Date
May 2009
Volume
8
Issue
5
Start / End Page
594 / 595
Location
England
Related Subject Headings
- Treatment Outcome
- Transplantation, Homologous
- Time Factors
- Respiratory System
- Middle Aged
- Male
- Humans
- Heart Valve Prosthesis Implantation
- Heart Transplantation
- Calcinosis
Citation
APA
Chicago
ICMJE
MLA
NLM
Joyce, D. L., Russell, S. D., Conte, J. V., & Cattaneo, S. M. (2009). Aortic valve replacement in a diseased bicuspid valve eleven years after transplantation. Interact Cardiovasc Thorac Surg, 8(5), 594–595. https://doi.org/10.1510/icvts.2008.194050
Joyce, David L., Stuart D. Russell, John V. Conte, and Stephen M. Cattaneo. “Aortic valve replacement in a diseased bicuspid valve eleven years after transplantation.” Interact Cardiovasc Thorac Surg 8, no. 5 (May 2009): 594–95. https://doi.org/10.1510/icvts.2008.194050.
Joyce DL, Russell SD, Conte JV, Cattaneo SM. Aortic valve replacement in a diseased bicuspid valve eleven years after transplantation. Interact Cardiovasc Thorac Surg. 2009 May;8(5):594–5.
Joyce, David L., et al. “Aortic valve replacement in a diseased bicuspid valve eleven years after transplantation.” Interact Cardiovasc Thorac Surg, vol. 8, no. 5, May 2009, pp. 594–95. Pubmed, doi:10.1510/icvts.2008.194050.
Joyce DL, Russell SD, Conte JV, Cattaneo SM. Aortic valve replacement in a diseased bicuspid valve eleven years after transplantation. Interact Cardiovasc Thorac Surg. 2009 May;8(5):594–595.

Published In
Interact Cardiovasc Thorac Surg
DOI
EISSN
1569-9285
Publication Date
May 2009
Volume
8
Issue
5
Start / End Page
594 / 595
Location
England
Related Subject Headings
- Treatment Outcome
- Transplantation, Homologous
- Time Factors
- Respiratory System
- Middle Aged
- Male
- Humans
- Heart Valve Prosthesis Implantation
- Heart Transplantation
- Calcinosis