BACKGROUND AND OBJECTIVE: As an increasing number of vitreoretinal surgeons are implanting retinal prosthesis devices, the need to share surgical techniques to ease implantation in challenging scenarios grows. The authors share a technique to aide in overcoming a challenge associated with uveal prolapse in a patient undergoing Argus II retinal prosthesis (Second Sight Medical Products, Sylmar, CA) implantation. PATIENTS AND METHODS: A surgical technique is discussed and demonstrated using a video (Video available at www.healio.com/OSLIRetina). RESULTS: A Sheets glide-assisted technique was used to successfully place the electrode array in the vitreous cavity. CONCLUSION: The Sheets glide may be a useful tool in aiding the retinal surgeon to successfully and easily place the electrode array of the Argus II retinal prosthesis. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:132-133.].

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Ophthalmic Surg Lasers Imaging Retina

DOI

EISSN

2325-8179

Publication Date

February 1, 2018

Volume

49

Issue

2

Start / End Page

132 / 133

Location

United States

Related Subject Headings

  • Visual Prosthesis
  • Visual Acuity
  • Retinitis Pigmentosa
  • Retina
  • Prosthesis Implantation
  • Ophthalmologic Surgical Procedures
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Finn, A. P., & Vajzovic, L. (2018). Sheets Glide-Assisted Intraocular Placement of the Argus II Retinal Prosthesis. Ophthalmic Surg Lasers Imaging Retina, 49(2), 132–133. https://doi.org/10.3928/23258160-20180129-08
Finn, Avni P., and Lejla Vajzovic. “Sheets Glide-Assisted Intraocular Placement of the Argus II Retinal Prosthesis.Ophthalmic Surg Lasers Imaging Retina 49, no. 2 (February 1, 2018): 132–33. https://doi.org/10.3928/23258160-20180129-08.
Finn AP, Vajzovic L. Sheets Glide-Assisted Intraocular Placement of the Argus II Retinal Prosthesis. Ophthalmic Surg Lasers Imaging Retina. 2018 Feb 1;49(2):132–3.
Finn, Avni P., and Lejla Vajzovic. “Sheets Glide-Assisted Intraocular Placement of the Argus II Retinal Prosthesis.Ophthalmic Surg Lasers Imaging Retina, vol. 49, no. 2, Feb. 2018, pp. 132–33. Pubmed, doi:10.3928/23258160-20180129-08.
Finn AP, Vajzovic L. Sheets Glide-Assisted Intraocular Placement of the Argus II Retinal Prosthesis. Ophthalmic Surg Lasers Imaging Retina. 2018 Feb 1;49(2):132–133.

Published In

Ophthalmic Surg Lasers Imaging Retina

DOI

EISSN

2325-8179

Publication Date

February 1, 2018

Volume

49

Issue

2

Start / End Page

132 / 133

Location

United States

Related Subject Headings

  • Visual Prosthesis
  • Visual Acuity
  • Retinitis Pigmentosa
  • Retina
  • Prosthesis Implantation
  • Ophthalmologic Surgical Procedures
  • Humans