Skip to main content

Internal-illumination photoacoustic computed tomography.

Publication ,  Journal Article
Li, M; Lan, B; Liu, W; Xia, J; Yao, J
Published in: Journal of biomedical optics
March 2018

We report a photoacoustic computed tomography (PACT) system using a customized optical fiber with a cylindrical diffuser to internally illuminate deep targets. The traditional external light illumination in PACT usually limits the penetration depth to a few centimeters from the tissue surface, mainly due to strong optical attenuation along the light propagation path from the outside in. By contrast, internal light illumination, with external ultrasound detection, can potentially detect much deeper targets. Different from previous internal illumination PACT implementations using forward-looking optical fibers, our internal-illumination PACT system uses a customized optical fiber with a 3-cm-long conoid needle diffuser attached to the fiber tip, which can homogeneously illuminate the surrounding space and substantially enlarge the field of view. We characterized the internal illumination distribution and PACT system performance. We performed tissue phantom and in vivo animal studies to further demonstrate the superior imaging depth using internal illumination over external illumination. We imaged a 7.5-cm-deep leaf target embedded in optically scattering medium and the beating heart of a mouse overlaid with 3.7-cm-thick chicken tissue. Our results have collectively demonstrated that the internal light illumination combined with external ultrasound detection might be a useful strategy to improve the penetration depth of PACT in imaging deep organs of large animals and humans.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Journal of biomedical optics

DOI

EISSN

1560-2281

ISSN

1083-3668

Publication Date

March 2018

Volume

23

Issue

3

Start / End Page

1 / 4

Related Subject Headings

  • Tomography, X-Ray Computed
  • Photoacoustic Techniques
  • Phantoms, Imaging
  • Optics
  • Muscles
  • Models, Biological
  • Mice
  • Humans
  • Hair
  • Equipment Design
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Li, M., Lan, B., Liu, W., Xia, J., & Yao, J. (2018). Internal-illumination photoacoustic computed tomography. Journal of Biomedical Optics, 23(3), 1–4. https://doi.org/10.1117/1.jbo.23.3.030506
Li, Mucong, Bangxin Lan, Wei Liu, Jun Xia, and Junjie Yao. “Internal-illumination photoacoustic computed tomography.Journal of Biomedical Optics 23, no. 3 (March 2018): 1–4. https://doi.org/10.1117/1.jbo.23.3.030506.
Li M, Lan B, Liu W, Xia J, Yao J. Internal-illumination photoacoustic computed tomography. Journal of biomedical optics. 2018 Mar;23(3):1–4.
Li, Mucong, et al. “Internal-illumination photoacoustic computed tomography.Journal of Biomedical Optics, vol. 23, no. 3, Mar. 2018, pp. 1–4. Epmc, doi:10.1117/1.jbo.23.3.030506.
Li M, Lan B, Liu W, Xia J, Yao J. Internal-illumination photoacoustic computed tomography. Journal of biomedical optics. 2018 Mar;23(3):1–4.

Published In

Journal of biomedical optics

DOI

EISSN

1560-2281

ISSN

1083-3668

Publication Date

March 2018

Volume

23

Issue

3

Start / End Page

1 / 4

Related Subject Headings

  • Tomography, X-Ray Computed
  • Photoacoustic Techniques
  • Phantoms, Imaging
  • Optics
  • Muscles
  • Models, Biological
  • Mice
  • Humans
  • Hair
  • Equipment Design