Argus II retinal prosthesis system: a review of patient selection criteria, surgical considerations, and post-operative outcomes.
Publication
, Journal Article
Finn, AP; Grewal, DS; Vajzovic, L
Published in: Clin Ophthalmol
2018
Retinitis pigmentosa (RP) is a group of heterogeneous inherited retinal degenerative disorders characterized by progressive rod and cone dysfunction and ensuing photoreceptor loss. Many patients suffer from legal blindness by their 40s or 50s. Artificial vision is considered once patients have lost all vision to the point of bare light perception or no light perception. The Argus II retinal prosthesis system is one such artificial vision device approved for patients with RP. This review focuses on the factors important for patient selection. Careful pre-operative screening, counseling, and management of patient expectations are critical for the successful implantation and visual rehabilitation of patients with the Argus II device.
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
Clin Ophthalmol
DOI
ISSN
1177-5467
Publication Date
2018
Volume
12
Start / End Page
1089 / 1097
Location
New Zealand
Related Subject Headings
- 3212 Ophthalmology and optometry
- 1113 Opthalmology and Optometry
Citation
APA
Chicago
ICMJE
MLA
NLM
Finn, A. P., Grewal, D. S., & Vajzovic, L. (2018). Argus II retinal prosthesis system: a review of patient selection criteria, surgical considerations, and post-operative outcomes. Clin Ophthalmol, 12, 1089–1097. https://doi.org/10.2147/OPTH.S137525
Finn, Avni P., Dilraj S. Grewal, and Lejla Vajzovic. “Argus II retinal prosthesis system: a review of patient selection criteria, surgical considerations, and post-operative outcomes.” Clin Ophthalmol 12 (2018): 1089–97. https://doi.org/10.2147/OPTH.S137525.
Finn AP, Grewal DS, Vajzovic L. Argus II retinal prosthesis system: a review of patient selection criteria, surgical considerations, and post-operative outcomes. Clin Ophthalmol. 2018;12:1089–97.
Finn, Avni P., et al. “Argus II retinal prosthesis system: a review of patient selection criteria, surgical considerations, and post-operative outcomes.” Clin Ophthalmol, vol. 12, 2018, pp. 1089–97. Pubmed, doi:10.2147/OPTH.S137525.
Finn AP, Grewal DS, Vajzovic L. Argus II retinal prosthesis system: a review of patient selection criteria, surgical considerations, and post-operative outcomes. Clin Ophthalmol. 2018;12:1089–1097.
Published In
Clin Ophthalmol
DOI
ISSN
1177-5467
Publication Date
2018
Volume
12
Start / End Page
1089 / 1097
Location
New Zealand
Related Subject Headings
- 3212 Ophthalmology and optometry
- 1113 Opthalmology and Optometry