Integrated radio-frequency/wireless coil design for simultaneous MR image acquisition and wireless communication.

Publication ,  Journal Article
Darnell, D; Cuthbertson, J; Robb, F; Song, AW; Truong, T-K
Published in: Magn Reson Med
March 2019

PURPOSE: An innovative radio-frequency (RF) coil design that allows RF currents both at the Larmor frequency and in a wireless communication band to flow on the same coil is proposed to enable simultaneous MRI signal reception and wireless data transfer, thereby minimizing the number of wired connections in the scanner without requiring any modifications or additional hardware within the scanner bore. METHODS: As a first application, the proposed integrated RF/wireless coil design was further combined with an integrated RF/shim coil design to perform not only MR image acquisition and wireless data transfer, but also localized B0 shimming with a single coil. Proof-of-concept phantom experiments were conducted with such a coil to demonstrate its ability to simultaneously perform these three functions, while maintaining the RF performance, wireless data integrity, and B0 shimming performance. RESULTS: Performing wirelessly controlled shimming of localized B0 inhomogeneities with the coil substantially reduced the B0 root-mean-square error (>70%) and geometric distortions in echo-planar images without degrading the image quality, signal-to-noise ratio (<1.7%), or wireless data throughput (maximum variance = 0.04 Mbps) of the coil. CONCLUSIONS: The RF/wireless coil design can provide a solution for wireless data transfer that can be easily integrated into existing MRI scanners for a variety of applications.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

March 2019

Volume

81

Issue

3

Start / End Page

2176 / 2183

Location

United States

Related Subject Headings

  • Wireless Technology
  • Software
  • Signal-To-Noise Ratio
  • Radio Waves
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Image Processing, Computer-Assisted
  • Humans
  • Equipment Design
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Darnell, D., Cuthbertson, J., Robb, F., Song, A. W., & Truong, T.-K. (2019). Integrated radio-frequency/wireless coil design for simultaneous MR image acquisition and wireless communication. Magn Reson Med, 81(3), 2176–2183. https://doi.org/10.1002/mrm.27513
Darnell, Dean, Jonathan Cuthbertson, Fraser Robb, Allen W. Song, and Trong-Kha Truong. “Integrated radio-frequency/wireless coil design for simultaneous MR image acquisition and wireless communication.Magn Reson Med 81, no. 3 (March 2019): 2176–83. https://doi.org/10.1002/mrm.27513.
Darnell D, Cuthbertson J, Robb F, Song AW, Truong T-K. Integrated radio-frequency/wireless coil design for simultaneous MR image acquisition and wireless communication. Magn Reson Med. 2019 Mar;81(3):2176–83.
Darnell, Dean, et al. “Integrated radio-frequency/wireless coil design for simultaneous MR image acquisition and wireless communication.Magn Reson Med, vol. 81, no. 3, Mar. 2019, pp. 2176–83. Pubmed, doi:10.1002/mrm.27513.
Darnell D, Cuthbertson J, Robb F, Song AW, Truong T-K. Integrated radio-frequency/wireless coil design for simultaneous MR image acquisition and wireless communication. Magn Reson Med. 2019 Mar;81(3):2176–2183.
Journal cover image

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

March 2019

Volume

81

Issue

3

Start / End Page

2176 / 2183

Location

United States

Related Subject Headings

  • Wireless Technology
  • Software
  • Signal-To-Noise Ratio
  • Radio Waves
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Image Processing, Computer-Assisted
  • Humans
  • Equipment Design