Skip to main content

Photon-counting cine-cardiac CT in the mouse

Publication ,  Journal Article
Clark, D; Holbrook, M; Lee, C-L; Badea, C
June 4, 2019

Abstract The maturation of photon-counting detector (PCD) technology promises to enhance routine CT imaging applications with high-fidelity spectral information. In this paper, we demonstrate the power of this synergy and our complementary reconstruction techniques, performing 4D, cardiac PCD-CT data acquisition and reconstruction in a mouse model of atherosclerosis, including calcified plaque. Specifically, in vivo cardiac micro-CT scans were performed in four ApoE knockout mice, following their development of calcified plaques. The scans were performed with a prototype PCD (DECTRIS, Ltd.) with 4 energy thresholds. Projection sampling was performed with 10 ms temporal resolution, allowing the reconstruction of 10 cardiac phases at each of 4 energies (40, 3D volumes per mouse scan). Reconstruction was performed iteratively using the split Bregman method with constraints on spectral rank and spatio-temporal gradient sparsity. The reconstructed images represent the first in vivo , 4D PCD-CT data in a mouse model of atherosclerosis. Robust regularization during iterative reconstruction yields high-fidelity results: an 8-fold reduction in noise standard deviation for the highest energy threshold (relative to algebraic reconstruction), while absolute spectral bias measurements remain below 13 Hounsfield units across all energy thresholds and scans. Qualitatively, image domain material decomposition results show clear separation of iodinated contrast and soft tissue from calcified plaque in the in vivo data. Quantitatively, spatial, spectral, and temporal fidelity are verified through a water phantom scan and a realistic MOBY phantom simulation experiment: spatial resolution is robustly preserved by iterative reconstruction (10% MTF: 2.8-3.0 lp/mm), left-ventricle, cardiac functional metrics can be measured from iodine map segmentations with ∼1% error, and small calcifications (615 μm) can be detected during slow moving phases of the cardiac cycle. Given these preliminary results, we believe that PCD technology will enhance dynamic CT imaging applications with high-fidelity spectral and material information.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

DOI

Publication Date

June 4, 2019
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Clark, D., Holbrook, M., Lee, C.-L., & Badea, C. (2019). Photon-counting cine-cardiac CT in the mouse. https://doi.org/10.1101/660100
Clark, Darin, Matthew Holbrook, Chang-Lung Lee, and Cristian Badea. “Photon-counting cine-cardiac CT in the mouse,” June 4, 2019. https://doi.org/10.1101/660100.
Clark D, Holbrook M, Lee C-L, Badea C. Photon-counting cine-cardiac CT in the mouse. 2019 Jun 4;
Clark, Darin, et al. Photon-counting cine-cardiac CT in the mouse. June 2019. Epmc, doi:10.1101/660100.
Clark D, Holbrook M, Lee C-L, Badea C. Photon-counting cine-cardiac CT in the mouse. 2019 Jun 4;

DOI

Publication Date

June 4, 2019