Skip to main content
Journal cover image

Preprocedural three-dimensional planning aids in transcatheter ductal stent placement: A single-center experience.

Publication ,  Journal Article
Chamberlain, RC; Ezekian, JE; Sturgeon, GM; Barker, PCA; Hill, KD; Fleming, GA
Published in: Catheter Cardiovasc Interv
May 1, 2020

OBJECTIVES: Describe the use of three-dimensional (3D) patent ductus arteriosus (PDA) modeling to better define ductal anatomy to improve preprocedural planning for ductal stent placement. BACKGROUND: Ductal stenting is an alternative to surgical shunting in patients with ductal dependent pulmonary blood flow. Ductal anatomy is often complex with extreme tortuosity and risk of pulmonary artery isolation, thus increasing procedural risks. METHODS: CT angiograms were segmented to produce 3D PDA models. Ductal morphology was characterized with attention to access approach, degree of pulmonary artery offset/risk of isolation and ductal tortuosity. 3D models were retrospectively compared with biplane angiography. RESULTS: 3D modeling was performed in 12 patients with adequate image quality for complete analysis in 11; median (interquartile range) age/weight 17 days (8-20 days) and 3.1 kg (2.4-3.9 kg). The PDA was reverse oriented in nine with average length of 17.2 ± 2.5 mm and high tortuosity (mean tortuosity index 52, range 3-108). From 3D modeling, two patients were excluded from ductal stenting-extreme ductal tortuosity and threatened pulmonary artery discontinuity, respectively. Ductal stenting was successful in the remaining nine with no major procedural complications. 3D modeling predicted a successful access approach based on the aortic orientation of the ductus in all patients (five carotid, two axillary, two femoral). When comparing 2D angiography with 3D models, angiography consistently underestimated ductal length (-3.2 mm ± 1.6 mm) and tortuosity (-14.8 ± 7.2). CONCLUSIONS: 3D modeling prior to ductal stent placement for ductal dependent pulmonary blood flow is useful in procedural planning, specifically for eligibility, access approach, and accurate ductal measurements. Further studies are needed to determine if 3D planning improves procedural outcomes.

Duke Scholars

Published In

Catheter Cardiovasc Interv

DOI

EISSN

1522-726X

Publication Date

May 1, 2020

Volume

95

Issue

6

Start / End Page

1141 / 1148

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Stents
  • Retrospective Studies
  • Radiographic Image Interpretation, Computer-Assisted
  • Pulmonary Circulation
  • Predictive Value of Tests
  • Patient-Specific Modeling
  • North Carolina
  • Models, Cardiovascular
  • Male
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chamberlain, R. C., Ezekian, J. E., Sturgeon, G. M., Barker, P. C. A., Hill, K. D., & Fleming, G. A. (2020). Preprocedural three-dimensional planning aids in transcatheter ductal stent placement: A single-center experience. Catheter Cardiovasc Interv, 95(6), 1141–1148. https://doi.org/10.1002/ccd.28669
Chamberlain, Reid C., Jordan E. Ezekian, Gregory M. Sturgeon, Piers C. A. Barker, Kevin D. Hill, and Gregory A. Fleming. “Preprocedural three-dimensional planning aids in transcatheter ductal stent placement: A single-center experience.Catheter Cardiovasc Interv 95, no. 6 (May 1, 2020): 1141–48. https://doi.org/10.1002/ccd.28669.
Chamberlain RC, Ezekian JE, Sturgeon GM, Barker PCA, Hill KD, Fleming GA. Preprocedural three-dimensional planning aids in transcatheter ductal stent placement: A single-center experience. Catheter Cardiovasc Interv. 2020 May 1;95(6):1141–8.
Chamberlain, Reid C., et al. “Preprocedural three-dimensional planning aids in transcatheter ductal stent placement: A single-center experience.Catheter Cardiovasc Interv, vol. 95, no. 6, May 2020, pp. 1141–48. Pubmed, doi:10.1002/ccd.28669.
Chamberlain RC, Ezekian JE, Sturgeon GM, Barker PCA, Hill KD, Fleming GA. Preprocedural three-dimensional planning aids in transcatheter ductal stent placement: A single-center experience. Catheter Cardiovasc Interv. 2020 May 1;95(6):1141–1148.
Journal cover image

Published In

Catheter Cardiovasc Interv

DOI

EISSN

1522-726X

Publication Date

May 1, 2020

Volume

95

Issue

6

Start / End Page

1141 / 1148

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Stents
  • Retrospective Studies
  • Radiographic Image Interpretation, Computer-Assisted
  • Pulmonary Circulation
  • Predictive Value of Tests
  • Patient-Specific Modeling
  • North Carolina
  • Models, Cardiovascular
  • Male