Skip to main content
Journal cover image

Midterm Success of a Custom, Non-Fluted, Diaphyseal, Press-Fit Stem Used With a Tumor Megaprosthesis System.

Publication ,  Journal Article
Visgauss, JD; Perrin, DL; Wilson, DA; Griffin, AM; Wunder, JS; Ferguson, PC
Published in: J Arthroplasty
May 2020

BACKGROUND: High rates of aseptic loosening with cemented prostheses have led to increased utilization of uncemented stems in the setting of megaprosthetic reconstruction. Theoretic concerns of rotational instability resulted in early stem designs with de-rotational mechanisms such as flutes or side plates. However, these designs have their own associated complications, and mechanical data suggest they are unnecessary. The purpose of this study is to evaluate outcomes and survivorship of an unfluted diaphyseal press-fit stem in the setting of megaprosthetic reconstruction. METHODS: Forty-five patients (46 stems), with a minimum 3-year follow-up, underwent reconstruction using 1 of 2 fully porous coated, unfluted, press-fit stems between 2005 and 2013: revision stem with adapter to the megaprosthesis (revision stem), or custom megaprosthesis stem (custom stem). Complications were described using the Henderson classification system, and subanalyses evaluated stem-related failures and survival. Radiographic evaluation of stem fixation was determined via evidence of bone bridging, spot welding, resorption, subsidence, and pedestal formation. Four patients had early stem removal for local recurrence or infection and were thus excluded from the radiographic analyses. RESULTS: Twenty-eight femoral (15 revision stem, 13 custom stem) and 14 tibial (6 revision stem, 8 custom stem) stems were reviewed. Average follow-up was 81 months (range, 42-140 months). Revision for implant-related complications occurred in 7 of 41 (17%), all in revision stems (3 adapter failures, 4 polyethylene wear). At final follow-up, all stems were retained without evidence of aseptic loosening, although 7 of 41 (17%) exhibited mild stress shielding. CONCLUSION: A non-fluted, press-fit stem used with a tumor prosthesis provided a stable bone-prosthesis interface at midterm follow-up.

Duke Scholars

Published In

J Arthroplasty

DOI

EISSN

1532-8406

Publication Date

May 2020

Volume

35

Issue

5

Start / End Page

1333 / 1338

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Reoperation
  • Prosthesis Failure
  • Prosthesis Design
  • Orthopedics
  • Neoplasms
  • Humans
  • Hip Prosthesis
  • Follow-Up Studies
  • Arthroplasty, Replacement, Hip
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Visgauss, J. D., Perrin, D. L., Wilson, D. A., Griffin, A. M., Wunder, J. S., & Ferguson, P. C. (2020). Midterm Success of a Custom, Non-Fluted, Diaphyseal, Press-Fit Stem Used With a Tumor Megaprosthesis System. J Arthroplasty, 35(5), 1333–1338. https://doi.org/10.1016/j.arth.2019.12.032
Visgauss, Julia D., David L. Perrin, David A. Wilson, Anthony M. Griffin, Jay S. Wunder, and Peter C. Ferguson. “Midterm Success of a Custom, Non-Fluted, Diaphyseal, Press-Fit Stem Used With a Tumor Megaprosthesis System.J Arthroplasty 35, no. 5 (May 2020): 1333–38. https://doi.org/10.1016/j.arth.2019.12.032.
Visgauss JD, Perrin DL, Wilson DA, Griffin AM, Wunder JS, Ferguson PC. Midterm Success of a Custom, Non-Fluted, Diaphyseal, Press-Fit Stem Used With a Tumor Megaprosthesis System. J Arthroplasty. 2020 May;35(5):1333–8.
Visgauss, Julia D., et al. “Midterm Success of a Custom, Non-Fluted, Diaphyseal, Press-Fit Stem Used With a Tumor Megaprosthesis System.J Arthroplasty, vol. 35, no. 5, May 2020, pp. 1333–38. Pubmed, doi:10.1016/j.arth.2019.12.032.
Visgauss JD, Perrin DL, Wilson DA, Griffin AM, Wunder JS, Ferguson PC. Midterm Success of a Custom, Non-Fluted, Diaphyseal, Press-Fit Stem Used With a Tumor Megaprosthesis System. J Arthroplasty. 2020 May;35(5):1333–1338.
Journal cover image

Published In

J Arthroplasty

DOI

EISSN

1532-8406

Publication Date

May 2020

Volume

35

Issue

5

Start / End Page

1333 / 1338

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Reoperation
  • Prosthesis Failure
  • Prosthesis Design
  • Orthopedics
  • Neoplasms
  • Humans
  • Hip Prosthesis
  • Follow-Up Studies
  • Arthroplasty, Replacement, Hip