Skip to main content
Journal cover image

A D2O detector for flux normalization of a pion decay-at-rest neutrino source

Publication ,  Journal Article
Akimov, D; An, P; Awe, C; Barbeau, PS; Becker, B; Belov, V; Bernardi, I; Blackston, MA; Bolozdynya, A; Cabrera-Palmer, B; Chernyak, D; Day, E ...
Published in: Journal of Instrumentation
August 1, 2021

We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncertainty in 2 years. This heavy-water detector will serve as the first module of a two-module detector system to ultimately measure the neutrino flux to 2-3% at both the First Target Station and the planned Second Target Station of the SNS. This detector will significantly reduce a dominant systematic uncertainty for neutrino cross-section measurements at the SNS, increasing the sensitivity of searches for new physics.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Journal of Instrumentation

DOI

EISSN

1748-0221

Publication Date

August 1, 2021

Volume

16

Issue

8

Related Subject Headings

  • Nuclear & Particles Physics
  • 51 Physical sciences
  • 40 Engineering
  • 09 Engineering
  • 02 Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Akimov, D., An, P., Awe, C., Barbeau, P. S., Becker, B., Belov, V., … Zettlemoyer, J. (2021). A D2O detector for flux normalization of a pion decay-at-rest neutrino source. Journal of Instrumentation, 16(8). https://doi.org/10.1088/1748-0221/16/08/P08048
Akimov, D., P. An, C. Awe, P. S. Barbeau, B. Becker, V. Belov, I. Bernardi, et al. “A D2O detector for flux normalization of a pion decay-at-rest neutrino source.” Journal of Instrumentation 16, no. 8 (August 1, 2021). https://doi.org/10.1088/1748-0221/16/08/P08048.
Akimov D, An P, Awe C, Barbeau PS, Becker B, Belov V, et al. A D2O detector for flux normalization of a pion decay-at-rest neutrino source. Journal of Instrumentation. 2021 Aug 1;16(8).
Akimov, D., et al. “A D2O detector for flux normalization of a pion decay-at-rest neutrino source.” Journal of Instrumentation, vol. 16, no. 8, Aug. 2021. Scopus, doi:10.1088/1748-0221/16/08/P08048.
Akimov D, An P, Awe C, Barbeau PS, Becker B, Belov V, Bernardi I, Blackston MA, Bolozdynya A, Cabrera-Palmer B, Chernyak D, Conley E, Daughhetee J, Day E, Detwiler J, Ding K, Durand MR, Efremenko Y, Elliott SR, Fabris L, Febbraro M, Gallo Rosso A, Galindo-Uribarri A, Green MP, Heath MR, Hedges S, Hoang D, Hughes M, Johnson T, Khromov A, Konovalov A, Koros J, Kozlova E, Kumpan A, Li L, Link JM, Liu J, Mann K, Markoff DM, Mastroberti J, Mueller PE, Newby J, Parno DS, Penttila SI, Pershey D, Rapp R, Ray H, Raybern J, Razuvaeva O, Reyna D, Rich GC, Ross J, Rudik D, Runge J, Salvat DJ, Salyapongse AM, Scholberg K, Shakirov A, Simakov G, Sinev G, Snow WM, Sosnovstsev V, Suh B, Tayloe R, Tellez-Giron-Flores K, Tolstukhin I, Ujah E, Vanderwerp J, Varner RL, Virtue CJ, Visser G, Ward EM, Wiseman C, Wongjirad T, Yen YR, Yoo J, Yu CH, Zettlemoyer J. A D2O detector for flux normalization of a pion decay-at-rest neutrino source. Journal of Instrumentation. 2021 Aug 1;16(8).
Journal cover image

Published In

Journal of Instrumentation

DOI

EISSN

1748-0221

Publication Date

August 1, 2021

Volume

16

Issue

8

Related Subject Headings

  • Nuclear & Particles Physics
  • 51 Physical sciences
  • 40 Engineering
  • 09 Engineering
  • 02 Physical Sciences