Skip to main content

Mucus Plugs in Asthma at CT Associated with Regional Ventilation Defects at 3He MRI.

Publication ,  Journal Article
Mummy, DG; Dunican, EM; Carey, KJ; Evans, MD; Elicker, BM; Newell, JD; Gierada, DS; Nagle, SK; Schiebler, ML; Sorkness, RL; Jarjour, NN ...
Published in: Radiology
April 2022

Background Airway mucus plugs in asthma are associated with exacerbation frequency, increased eosinophilia, and reduced lung function. The relationship between mucus plugs and spatially overlapping ventilation abnormalities observed at hyperpolarized gas MRI has not been assessed quantitatively. Purpose To assess regional associations between CT mucus plugs scored by individual bronchopulmonary segment and corresponding measurements of segmental ventilation defect percentage (VDP) at hyperpolarized helium 3 (3He) MRI. Materials and Methods In this secondary analysis of a Health Insurance Portability and Accountability Act-compliant prospective observational cohort, participants in the Severe Asthma Research Program (SARP) III (NCT01760915) between December 2012 and August 2015 underwent hyperpolarized 3He MRI to determine segmental VDP. Segmental mucus plugs at CT were scored by two readers, with segments scored as plugged only if both readers agreed independently. A linear mixed-effects model controlling for interpatient variability was then used to assess differences in VDP in plugged versus plug-free segments. Results Forty-four participants with asthma were assessed (mean age ± standard deviation, 47 years ± 15; 29 women): 19 with mild-to-moderate asthma and 25 with severe asthma. Mucus plugs were observed in 49 total bronchopulmonary segments across eight of 44 patients. Segments containing mucus plugs had a median segmental VDP of 25.9% (25th-75th percentile, 7.3%-38.3%) versus 1.4% (25th-75th percentile, 0.1%-5.2%; P < .001) in plug-free segments. Similarly, the model estimated a segmental VDP of 18.9% (95% CI: 15.7, 22.2) for mucus-plugged segments versus 5.1% (95% CI: 3.3, 7.0) for plug-free segments (P < .001). Participants with one or more mucus plugs had a median whole-lung VDP of 11.1% (25th-75th percentile, 7.1%-18.9%) versus 3.1% (25th-75th percentile, 1.1%-4.4%) in those without plugs (P < .001). Conclusion Airway mucus plugging at CT was associated with reduced ventilation in the same bronchopulmonary segment at hyperpolarized helium 3 MRI, suggesting that mucus plugging may be an important cause of ventilation defects in asthma. © RSNA, 2021 Online supplemental material is available for this article.

Duke Scholars

Published In

Radiology

DOI

EISSN

1527-1315

ISSN

0033-8419

Publication Date

April 2022

Volume

303

Issue

1

Start / End Page

184 / 190

Related Subject Headings

  • Tomography, X-Ray Computed
  • Respiration Disorders
  • Nuclear Medicine & Medical Imaging
  • Mucus
  • Male
  • Magnetic Resonance Imaging
  • Lung
  • Humans
  • Helium
  • Female
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Mummy, D. G., Dunican, E. M., Carey, K. J., Evans, M. D., Elicker, B. M., Newell, J. D., … Fain, S. B. (2022). Mucus Plugs in Asthma at CT Associated with Regional Ventilation Defects at 3He MRI. Radiology, 303(1), 184–190. https://doi.org/10.1148/radiol.2021204616
Mummy, David G., Eleanor M. Dunican, Katherine J. Carey, Michael D. Evans, Brett M. Elicker, John D. Newell, David S. Gierada, et al. “Mucus Plugs in Asthma at CT Associated with Regional Ventilation Defects at 3He MRI.Radiology 303, no. 1 (April 2022): 184–90. https://doi.org/10.1148/radiol.2021204616.
Mummy DG, Dunican EM, Carey KJ, Evans MD, Elicker BM, Newell JD, et al. Mucus Plugs in Asthma at CT Associated with Regional Ventilation Defects at 3He MRI. Radiology. 2022 Apr;303(1):184–90.
Mummy, David G., et al. “Mucus Plugs in Asthma at CT Associated with Regional Ventilation Defects at 3He MRI.Radiology, vol. 303, no. 1, Apr. 2022, pp. 184–90. Epmc, doi:10.1148/radiol.2021204616.
Mummy DG, Dunican EM, Carey KJ, Evans MD, Elicker BM, Newell JD, Gierada DS, Nagle SK, Schiebler ML, Sorkness RL, Jarjour NN, Denlinger LC, Fahy JV, Fain SB. Mucus Plugs in Asthma at CT Associated with Regional Ventilation Defects at 3He MRI. Radiology. 2022 Apr;303(1):184–190.

Published In

Radiology

DOI

EISSN

1527-1315

ISSN

0033-8419

Publication Date

April 2022

Volume

303

Issue

1

Start / End Page

184 / 190

Related Subject Headings

  • Tomography, X-Ray Computed
  • Respiration Disorders
  • Nuclear Medicine & Medical Imaging
  • Mucus
  • Male
  • Magnetic Resonance Imaging
  • Lung
  • Humans
  • Helium
  • Female