To compare 7-pinhole and single-pinhole SPECT thyroid imaging under conditions of equal total detector area. A phantom was generated using XCAT software. Trajectories of 7-pinhole and single-pinhole detectors were developed for 2 scenarios: (i) minimum radius of rotation (D_PH) for fully viewing a target imaging sphere containing the thyroid and (ii) minimum radii of rotation for fully viewing the target imaging sphere and avoiding collision with the patient. Projection data were computer-simulated and images were reconstructed modeling attenuation, spatial resolution, and Poisson noise. Seven-pinhole and single-pinhole systems were compared for a range of lesion-activity concentrations, pinhole diameters, and half opening angles. Comparison metrics included system resolution, geometric sensitivity, and image quality. In the absence of collision constraints, 7-pinhole systems show potential to provide better trade-offs between geometric sensitivity and spatial resolution. However, when pinhole trajectories are constrained to avoid patient collision, 7-pinhole systems may be affected more adversely than single pinhole systems. The study points to the potential of 7-pinhole systems and to the importance of addressing collision constraints.

Duke Scholars

Published In

2020 IEEE Nuclear Science Symposium and Medical Imaging Conference NSS Mic 2020

DOI

Publication Date

January 1, 2020
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Yu, T., Reiman, R. E., & Bowsher, J. E. (2020). Seven-Pinhole Versus Single-Pinhole SPECT for Thyroid Imaging. In 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference NSS Mic 2020. https://doi.org/10.1109/NSS/MIC42677.2020.9507803
Yu, T., R. E. Reiman, and J. E. Bowsher. “Seven-Pinhole Versus Single-Pinhole SPECT for Thyroid Imaging.” In 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference NSS Mic 2020, 2020. https://doi.org/10.1109/NSS/MIC42677.2020.9507803.
Yu T, Reiman RE, Bowsher JE. Seven-Pinhole Versus Single-Pinhole SPECT for Thyroid Imaging. In: 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference NSS Mic 2020. 2020.
Yu, T., et al. “Seven-Pinhole Versus Single-Pinhole SPECT for Thyroid Imaging.” 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference NSS Mic 2020, 2020. Scopus, doi:10.1109/NSS/MIC42677.2020.9507803.
Yu T, Reiman RE, Bowsher JE. Seven-Pinhole Versus Single-Pinhole SPECT for Thyroid Imaging. 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference NSS Mic 2020. 2020.

Published In

2020 IEEE Nuclear Science Symposium and Medical Imaging Conference NSS Mic 2020

DOI

Publication Date

January 1, 2020