Skip to main content
Journal cover image

Safety and efficacy of using 2.4/2.4 mm and 2.0/2.4 mm dual mini-fragment plate combinations for fixation of displaced diaphyseal clavicle fractures.

Publication ,  Journal Article
Chen, MJ; DeBaun, MR; Salazar, BP; Lai, C; Bishop, JA; Gardner, MJ
Published in: Injury
March 2020

PURPOSE: The purpose of this study was to evaluate the safety and efficacy of using lower profile 2.4/2.4 mm and 2.0/2.4 mm dual mini-fragment plate constructs for fixation of diaphyseal clavicle fractures. METHODS: This was a retrospective case series of all displaced diaphyseal clavicle fractures treated with 2.4/2.4 and 2.0/2.4 dual mini-fragment plate constructs at a single level-one trauma center. Postoperative complications and fracture healing rates were recorded. A subset of patients with long-term follow up was used to determine the rate of reoperation for symptomatic implant removal. RESULTS: All 36 identified fractures healed without loss of reduction or implant failure. There was one superficial infection and no deep infections or cases of wound dehiscence. Twenty patients from the entire cohort had longer-term follow up available to assess the reoperation rate for symptomatic implant removal. Two patients (10%) underwent symptomatic implant removal, and one patient with retained implants was planning on future removal due to soft-tissue irritation; this combined to a projected reoperation rate of 15% for symptomatic implant removal. CONCLUSION: Dual mini-fragment plating of diaphyseal clavicle fractures, using 2.4/2.4 mm and 2.0/2.4 mm plate combinations, creates a lower profile construct that reliably maintains fracture reduction to healing, and has a low rate of reoperation for symptomatic implant removal.

Duke Scholars

Published In

Injury

DOI

EISSN

1879-0267

Publication Date

March 2020

Volume

51

Issue

3

Start / End Page

647 / 650

Location

Netherlands

Related Subject Headings

  • Young Adult
  • Retrospective Studies
  • Reoperation
  • Postoperative Complications
  • Orthopedics
  • Middle Aged
  • Male
  • Humans
  • Fractures, Bone
  • Fracture Healing
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chen, M. J., DeBaun, M. R., Salazar, B. P., Lai, C., Bishop, J. A., & Gardner, M. J. (2020). Safety and efficacy of using 2.4/2.4 mm and 2.0/2.4 mm dual mini-fragment plate combinations for fixation of displaced diaphyseal clavicle fractures. Injury, 51(3), 647–650. https://doi.org/10.1016/j.injury.2020.01.014
Chen, Michael J., Malcolm R. DeBaun, Brett P. Salazar, Cara Lai, Julius A. Bishop, and Michael J. Gardner. “Safety and efficacy of using 2.4/2.4 mm and 2.0/2.4 mm dual mini-fragment plate combinations for fixation of displaced diaphyseal clavicle fractures.Injury 51, no. 3 (March 2020): 647–50. https://doi.org/10.1016/j.injury.2020.01.014.
Chen, Michael J., et al. “Safety and efficacy of using 2.4/2.4 mm and 2.0/2.4 mm dual mini-fragment plate combinations for fixation of displaced diaphyseal clavicle fractures.Injury, vol. 51, no. 3, Mar. 2020, pp. 647–50. Pubmed, doi:10.1016/j.injury.2020.01.014.
Journal cover image

Published In

Injury

DOI

EISSN

1879-0267

Publication Date

March 2020

Volume

51

Issue

3

Start / End Page

647 / 650

Location

Netherlands

Related Subject Headings

  • Young Adult
  • Retrospective Studies
  • Reoperation
  • Postoperative Complications
  • Orthopedics
  • Middle Aged
  • Male
  • Humans
  • Fractures, Bone
  • Fracture Healing