Skip to main content
Journal cover image

Time Window of Head Impact Kinematics Measurement for Calculation of Brain Strain and Strain Rate in American Football.

Publication ,  Journal Article
Liu, Y; Domel, AG; Cecchi, NJ; Rice, E; Callan, AA; Raymond, SJ; Zhou, Z; Zhan, X; Li, Y; Zeineh, MM; Grant, GA; Camarillo, DB
Published in: Ann Biomed Eng
October 2021

Wearable devices have been shown to effectively measure the head's movement during impacts in sports like American football. When a head impact occurs, the device is triggered to collect and save the kinematic measurements during a predefined time window. Then, based on the collected kinematics, finite element (FE) head models can calculate brain strain and strain rate, which are used to evaluate the risk of mild traumatic brain injury. To find a time window that can provide a sufficient duration of kinematics for FE analysis, we investigated 118 on-field video-confirmed football head impacts collected by the Stanford Instrumented Mouthguard. The simulation results based on the kinematics truncated to a shorter time window were compared with the original to determine the minimum time window needed for football. Because the individual differences in brain geometry influence these calculations, we included six representative brain geometries and found that larger brains need a longer time window of kinematics for accurate calculation. Among the different sizes of brains, a pre-trigger time of 40 ms and a post-trigger time of 70 ms were found to yield calculations of brain strain and strain rate that were not significantly different from calculations using the original 200 ms time window recorded by the mouthguard. Therefore, approximately 110 ms is recommended for complete modeling of impacts for football.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Ann Biomed Eng

DOI

EISSN

1573-9686

Publication Date

October 2021

Volume

49

Issue

10

Start / End Page

2791 / 2804

Location

United States

Related Subject Headings

  • Wearable Electronic Devices
  • United States
  • Telemetry
  • Sports Equipment
  • Mouth Protectors
  • Models, Biological
  • Male
  • Humans
  • Head
  • Football
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Liu, Y., Domel, A. G., Cecchi, N. J., Rice, E., Callan, A. A., Raymond, S. J., … Camarillo, D. B. (2021). Time Window of Head Impact Kinematics Measurement for Calculation of Brain Strain and Strain Rate in American Football. Ann Biomed Eng, 49(10), 2791–2804. https://doi.org/10.1007/s10439-021-02821-z
Liu, Yuzhe, August G. Domel, Nicholas J. Cecchi, Eli Rice, Ashlyn A. Callan, Samuel J. Raymond, Zhou Zhou, et al. “Time Window of Head Impact Kinematics Measurement for Calculation of Brain Strain and Strain Rate in American Football.Ann Biomed Eng 49, no. 10 (October 2021): 2791–2804. https://doi.org/10.1007/s10439-021-02821-z.
Liu Y, Domel AG, Cecchi NJ, Rice E, Callan AA, Raymond SJ, et al. Time Window of Head Impact Kinematics Measurement for Calculation of Brain Strain and Strain Rate in American Football. Ann Biomed Eng. 2021 Oct;49(10):2791–804.
Liu, Yuzhe, et al. “Time Window of Head Impact Kinematics Measurement for Calculation of Brain Strain and Strain Rate in American Football.Ann Biomed Eng, vol. 49, no. 10, Oct. 2021, pp. 2791–804. Pubmed, doi:10.1007/s10439-021-02821-z.
Liu Y, Domel AG, Cecchi NJ, Rice E, Callan AA, Raymond SJ, Zhou Z, Zhan X, Li Y, Zeineh MM, Grant GA, Camarillo DB. Time Window of Head Impact Kinematics Measurement for Calculation of Brain Strain and Strain Rate in American Football. Ann Biomed Eng. 2021 Oct;49(10):2791–2804.
Journal cover image

Published In

Ann Biomed Eng

DOI

EISSN

1573-9686

Publication Date

October 2021

Volume

49

Issue

10

Start / End Page

2791 / 2804

Location

United States

Related Subject Headings

  • Wearable Electronic Devices
  • United States
  • Telemetry
  • Sports Equipment
  • Mouth Protectors
  • Models, Biological
  • Male
  • Humans
  • Head
  • Football