Analysis identifying minimal governing parameters for clinically accurate in silico fractional flow reserve.

Publication ,  Journal Article
Tanade, C; Chen, SJ; Leopold, JA; Randles, A
Published in: Frontiers in medical technology
January 2022

Personalized hemodynamic models can accurately compute fractional flow reserve (FFR) from coronary angiograms and clinical measurements (FFR baseline ), but obtaining patient-specific data could be challenging and sometimes not feasible. Understanding which measurements need to be patient-tuned vs. patient-generalized would inform models with minimal inputs that could expedite data collection and simulation pipelines.To determine the minimum set of patient-specific inputs to compute FFR using invasive measurement of FFR (FFR invasive ) as gold standard.Personalized coronary geometries ( N = 50 ) were derived from patient coronary angiograms. A computational fluid dynamics framework, FFR baseline , was parameterized with patient-specific inputs: coronary geometry, stenosis geometry, mean arterial pressure, cardiac output, heart rate, hematocrit, and distal pressure location. FFR baseline was validated against FFR invasive and used as the baseline to elucidate the impact of uncertainty on personalized inputs through global uncertainty analysis. FFR streamlined was created by only incorporating the most sensitive inputs and FFR semi-streamlined additionally included patient-specific distal location.FFR baseline was validated against FFR invasive via correlation ( r = 0.714 , p < 0.001 ), agreement (mean difference: 0.01 ± 0.09 ), and diagnostic performance (sensitivity: 89.5%, specificity: 93.6%, PPV: 89.5%, NPV: 93.6%, AUC: 0.95). FFR semi-streamlined provided identical diagnostic performance with FFR baseline . Compared to FFR baseline vs. FFR invasive , FFR streamlined vs. FFR invasive had decreased correlation ( r = 0.64 , p < 0.001 ), improved agreement (mean difference: 0.01 ± 0.08 ), and comparable diagnostic performance (sensitivity: 79.0%, specificity: 90.3%, PPV: 83.3%, NPV: 87.5%, AUC: 0.90).Streamlined models could match the diagnostic performance of the baseline with a full gamut of patient-specific measurements. Capturing coronary hemodynamics depended most on accurate geometry reconstruction and cardiac output measurement.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Frontiers in medical technology

DOI

EISSN

2673-3129

ISSN

2673-3129

Publication Date

January 2022

Volume

4

Start / End Page

1034801

Related Subject Headings

  • 3206 Medical biotechnology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tanade, C., Chen, S. J., Leopold, J. A., & Randles, A. (2022). Analysis identifying minimal governing parameters for clinically accurate in silico fractional flow reserve. Frontiers in Medical Technology, 4, 1034801. https://doi.org/10.3389/fmedt.2022.1034801
Tanade, Cyrus, S James Chen, Jane A. Leopold, and Amanda Randles. “Analysis identifying minimal governing parameters for clinically accurate in silico fractional flow reserve.Frontiers in Medical Technology 4 (January 2022): 1034801. https://doi.org/10.3389/fmedt.2022.1034801.
Tanade C, Chen SJ, Leopold JA, Randles A. Analysis identifying minimal governing parameters for clinically accurate in silico fractional flow reserve. Frontiers in medical technology. 2022 Jan;4:1034801.
Tanade, Cyrus, et al. “Analysis identifying minimal governing parameters for clinically accurate in silico fractional flow reserve.Frontiers in Medical Technology, vol. 4, Jan. 2022, p. 1034801. Epmc, doi:10.3389/fmedt.2022.1034801.
Tanade C, Chen SJ, Leopold JA, Randles A. Analysis identifying minimal governing parameters for clinically accurate in silico fractional flow reserve. Frontiers in medical technology. 2022 Jan;4:1034801.

Published In

Frontiers in medical technology

DOI

EISSN

2673-3129

ISSN

2673-3129

Publication Date

January 2022

Volume

4

Start / End Page

1034801

Related Subject Headings

  • 3206 Medical biotechnology