Skip to main content
Journal cover image

Test battery for assessing vascular disturbances of fingers.

Publication ,  Journal Article
Lindsell, CJ
Published in: Environ Health Prev Med
November 2005

The diagnosis of vibration-induced white finger (VWF) is difficult, often relying on medical interview and history. The condition is characterized by an exaggerated vasoconstriction of digital arteries in response to cold. The complete closure of digital arteries is episodic and results in a characteristic blanching that is rarely observed by a clinician. Objective measurements of the response of the digital circulation to cold can assist in evaluating a patient for VWF. Finger systolic blood pressure (FSBP) following local cooling is a measure of cold-induced vasoconstriction in digital arteries and is an assessment of vasomotor tone. Low FSBPs following cooling are indicative of dysfunction. Finger skin temperature (FST) following hand cooling is a measure of cutaneous blood flow. The mechanism underlying the recovery of cutaneous blood flow following cooling is as yet not fully understood, but a delayed recovery is believed to arise from persistent vascular disturbances of the fingers or from a resulting in conflicting opinions concerning the utility of the measurements, a scarcity of comparable data from epidemiological investigations, and limited normative data to aid clinicians in decision-making. This review of evidence on which the tests are based is aimed at providing clinicians and researchers with an understanding of the factors that must be considered when conducting the tests, interpreting the results, and comparing results between different studies.

Duke Scholars

Published In

Environ Health Prev Med

DOI

ISSN

1342-078X

Publication Date

November 2005

Volume

10

Issue

6

Start / End Page

341 / 350

Location

Japan

Related Subject Headings

  • Toxicology
  • 4206 Public health
  • 11 Medical and Health Sciences
  • 06 Biological Sciences
  • 05 Environmental Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Lindsell, C. J. (2005). Test battery for assessing vascular disturbances of fingers. Environ Health Prev Med, 10(6), 341–350. https://doi.org/10.1007/BF02898195
Lindsell, Christopher J. “Test battery for assessing vascular disturbances of fingers.Environ Health Prev Med 10, no. 6 (November 2005): 341–50. https://doi.org/10.1007/BF02898195.
Lindsell CJ. Test battery for assessing vascular disturbances of fingers. Environ Health Prev Med. 2005 Nov;10(6):341–50.
Lindsell, Christopher J. “Test battery for assessing vascular disturbances of fingers.Environ Health Prev Med, vol. 10, no. 6, Nov. 2005, pp. 341–50. Pubmed, doi:10.1007/BF02898195.
Lindsell CJ. Test battery for assessing vascular disturbances of fingers. Environ Health Prev Med. 2005 Nov;10(6):341–350.
Journal cover image

Published In

Environ Health Prev Med

DOI

ISSN

1342-078X

Publication Date

November 2005

Volume

10

Issue

6

Start / End Page

341 / 350

Location

Japan

Related Subject Headings

  • Toxicology
  • 4206 Public health
  • 11 Medical and Health Sciences
  • 06 Biological Sciences
  • 05 Environmental Sciences