Skip to main content
Journal cover image

KeyLoop retractor for global gasless laparoscopy: evaluation of safety and feasibility in a porcine model.

Publication ,  Journal Article
Zadey, S; Leraas, H; Gupta, A; Biswas, A; Hollier, P; Vissoci, JRN; Mugaga, J; Ssekitoleko, RT; Everitt, JI; Loh, AHP; Lee, YT; Saterbak, A ...
Published in: Surg Endosc
August 2023

BACKGROUND: Many surgeons in low- and middle-income countries have described performing surgery using gasless (lift) laparoscopy due to inaccessibility of carbon dioxide and reliable electricity, but the safety and feasibility of the technique has not been well documented. We describe preclinical testing of the in vivo safety and utility of KeyLoop, a laparoscopic retractor system to enable gasless laparoscopy. METHODS: Experienced laparoscopic surgeons completed a series of four laparoscopic tasks in a porcine model: laparoscopic exposure, small bowel resection, intracorporeal suturing with knot tying, and cholecystectomy. For each participating surgeon, the four tasks were completed in a practice animal using KeyLoop. Surgeons then completed these tasks using standard-of-care (SOC) gas laparoscopy and KeyLoop in block randomized order to minimize learning curve effect. Vital signs, task completion time, blood loss and surgical complications were compared between SOC and KeyLoop using paired nonparametric tests. Surgeons completed a survey on use of KeyLoop compared to gas laparoscopy. Abdominal wall tissue was evaluated for injury by a blinded pathologist. RESULTS: Five surgeons performed 60 tasks in 15 pigs. There were no significant differences in times to complete the tasks between KeyLoop and SOC. For all tasks, there was a learning curve with task completion times related to learning the porcine model. There were no significant differences in blood loss, vital signs or surgical complications between KeyLoop and SOC. Eleven surgeons from the United States and Singapore felt that KeyLoop could be used to safely perform several common surgical procedures. No abdominal wall tissue injury was observed for either KeyLoop or SOC. CONCLUSIONS: Procedure times, blood loss, abdominal wall tissue injury and surgical complications were similar between KeyLoop and SOC gas laparoscopy for basic surgical procedures. This data supports KeyLoop as a useful tool to increase access to laparoscopy in low- and middle-income countries.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Surg Endosc

DOI

EISSN

1432-2218

Publication Date

August 2023

Volume

37

Issue

8

Start / End Page

5943 / 5955

Location

Germany

Related Subject Headings

  • Swine
  • Surgery
  • Laparoscopy
  • Feasibility Studies
  • Cholecystectomy
  • Carbon Dioxide
  • Animals
  • Abdominal Wall
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Zadey, S., Leraas, H., Gupta, A., Biswas, A., Hollier, P., Vissoci, J. R. N., … Fitzgerald, T. N. (2023). KeyLoop retractor for global gasless laparoscopy: evaluation of safety and feasibility in a porcine model. Surg Endosc, 37(8), 5943–5955. https://doi.org/10.1007/s00464-023-10054-5
Zadey, Siddhesh, Harold Leraas, Aryaman Gupta, Arushi Biswas, Pierce Hollier, Joao Ricardo Nickenig Vissoci, Julius Mugaga, et al. “KeyLoop retractor for global gasless laparoscopy: evaluation of safety and feasibility in a porcine model.Surg Endosc 37, no. 8 (August 2023): 5943–55. https://doi.org/10.1007/s00464-023-10054-5.
Zadey S, Leraas H, Gupta A, Biswas A, Hollier P, Vissoci JRN, et al. KeyLoop retractor for global gasless laparoscopy: evaluation of safety and feasibility in a porcine model. Surg Endosc. 2023 Aug;37(8):5943–55.
Zadey, Siddhesh, et al. “KeyLoop retractor for global gasless laparoscopy: evaluation of safety and feasibility in a porcine model.Surg Endosc, vol. 37, no. 8, Aug. 2023, pp. 5943–55. Pubmed, doi:10.1007/s00464-023-10054-5.
Zadey S, Leraas H, Gupta A, Biswas A, Hollier P, Vissoci JRN, Mugaga J, Ssekitoleko RT, Everitt JI, Loh AHP, Lee YT, Saterbak A, Mueller JL, Fitzgerald TN. KeyLoop retractor for global gasless laparoscopy: evaluation of safety and feasibility in a porcine model. Surg Endosc. 2023 Aug;37(8):5943–5955.
Journal cover image

Published In

Surg Endosc

DOI

EISSN

1432-2218

Publication Date

August 2023

Volume

37

Issue

8

Start / End Page

5943 / 5955

Location

Germany

Related Subject Headings

  • Swine
  • Surgery
  • Laparoscopy
  • Feasibility Studies
  • Cholecystectomy
  • Carbon Dioxide
  • Animals
  • Abdominal Wall
  • 3202 Clinical sciences
  • 1103 Clinical Sciences