Skip to main content

Utility of Photon-Counting Detector CT Myelography for the Detection of CSF-Venous Fistulas.

Publication ,  Journal Article
Madhavan, AA; Yu, L; Brinjikji, W; Cutsforth-Gregory, JK; Schwartz, FR; Mark, IT; Benson, JC; Amrhein, TJ
Published in: AJNR Am J Neuroradiol
June 2023

CSF-venous fistulas are an increasingly recognized type of CSF leak that can be particularly challenging to detect, even with recently improved imaging techniques. Currently, most institutions use decubitus digital subtraction myelography or dynamic CT myelography to localize CSF-venous fistulas. Photon-counting detector CT is a relatively recent advancement that has many theoretical benefits, including excellent spatial resolution, high temporal resolution, and spectral imaging capabilities. We describe 6 cases of CSF-venous fistulas detected on decubitus photon-counting detector CT myelography. In 5 of these cases, the CSF-venous fistula was previously occult on decubitus digital subtraction myelography or decubitus dynamic CT myelography using an energy-integrating detector system. All 6 cases exemplify the potential benefits of photon-counting detector CT myelography in identifying CSF-venous fistulas. We suggest that further implementation of this imaging technique will likely be valuable to improve the detection of fistulas that might otherwise be missed with currently used techniques.

Duke Scholars

Published In

AJNR Am J Neuroradiol

DOI

EISSN

1936-959X

Publication Date

June 2023

Volume

44

Issue

6

Start / End Page

740 / 744

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Nuclear Medicine & Medical Imaging
  • Myelography
  • Intracranial Hypotension
  • Humans
  • Fistula
  • Cerebrospinal Fluid Leak
  • 3406 Physical chemistry
  • 3209 Neurosciences
  • 3202 Clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Madhavan, A. A., Yu, L., Brinjikji, W., Cutsforth-Gregory, J. K., Schwartz, F. R., Mark, I. T., … Amrhein, T. J. (2023). Utility of Photon-Counting Detector CT Myelography for the Detection of CSF-Venous Fistulas. AJNR Am J Neuroradiol, 44(6), 740–744. https://doi.org/10.3174/ajnr.A7887
Madhavan, A. A., L. Yu, W. Brinjikji, J. K. Cutsforth-Gregory, F. R. Schwartz, I. T. Mark, J. C. Benson, and T. J. Amrhein. “Utility of Photon-Counting Detector CT Myelography for the Detection of CSF-Venous Fistulas.AJNR Am J Neuroradiol 44, no. 6 (June 2023): 740–44. https://doi.org/10.3174/ajnr.A7887.
Madhavan AA, Yu L, Brinjikji W, Cutsforth-Gregory JK, Schwartz FR, Mark IT, et al. Utility of Photon-Counting Detector CT Myelography for the Detection of CSF-Venous Fistulas. AJNR Am J Neuroradiol. 2023 Jun;44(6):740–4.
Madhavan, A. A., et al. “Utility of Photon-Counting Detector CT Myelography for the Detection of CSF-Venous Fistulas.AJNR Am J Neuroradiol, vol. 44, no. 6, June 2023, pp. 740–44. Pubmed, doi:10.3174/ajnr.A7887.
Madhavan AA, Yu L, Brinjikji W, Cutsforth-Gregory JK, Schwartz FR, Mark IT, Benson JC, Amrhein TJ. Utility of Photon-Counting Detector CT Myelography for the Detection of CSF-Venous Fistulas. AJNR Am J Neuroradiol. 2023 Jun;44(6):740–744.

Published In

AJNR Am J Neuroradiol

DOI

EISSN

1936-959X

Publication Date

June 2023

Volume

44

Issue

6

Start / End Page

740 / 744

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Nuclear Medicine & Medical Imaging
  • Myelography
  • Intracranial Hypotension
  • Humans
  • Fistula
  • Cerebrospinal Fluid Leak
  • 3406 Physical chemistry
  • 3209 Neurosciences
  • 3202 Clinical sciences