In Pursuit of the Optimal Dusting Settings with the Thulium Fiber Laser: An In Vitro Assessment.

Publication ,  Journal Article
Soto-Palou, F; Chen, J; Medairos, R; Zhong, P; Antonelli, J; Preminger, GM; Lipkin, ME
Published in: J Endourol
August 2023

Objective: Low energy and high frequency settings are used in stone dusting for holmium lasers. Such settings may not be optimal for thulium fiber laser (TFL). With the seemingly endless combination of settings, we aim to provide guidance to the practicing urologists and assess the efficiency of the TFL platform in an automated in vitro "dusting model." Materials/Methods: Three experimental setups were designed to investigate stone dusting produced by an IPG Photonics TLR-50 W TFL system using 200 μm fiber and soft BegoStone phantoms. The most popular 10 and 20 W dusting settings among endourologist familiar with TFL were evaluated. We directly compared short pulse (SP) vs long pulse (LP) mode using various combinations of pulse energy (Ep) and pulse frequency (F). Thereafter, we tested the 10 and 20 W settings and compared them among each other to elucidate the most efficient settings at each power. Treatments were performed under the same total laser energy delivered to the stone at four different standoff distances (SDs) with a clinically relevant scanning speed of either 1 or 2 mm/sec. Ablation volumes were quantified by optical coherence tomography to assess stone dusting efficiency. Fragment size after ablation at different pulse energies was evaluated by sieving and evaluating under a microscope after treatment. Results: Overall, SP provided greater ablation volume when compared with LP. Our dusting efficiency model demonstrated that the maximum stone ablation was achieved at the combination of high energy/low frequency settings (p < 0.005) and at a SD of 0.2 mm. At all tested pulse energies, no stone phantoms were broken into fragments >1 mm. Conclusions: During stone dusting with TFL, SP offers superior ablation to LP settings. Optimal dusting at clinically relevant scanning speeds of 1 and 2 mm/sec occurs at high energy/low frequency settings. Thulium lithotripsy with high Ep does not result in increased fragment size.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Endourol

DOI

EISSN

1557-900X

Publication Date

August 2023

Volume

37

Issue

8

Start / End Page

914 / 920

Location

United States

Related Subject Headings

  • Urology & Nephrology
  • Urinary Calculi
  • Thulium
  • Lithotripsy, Laser
  • Lasers, Solid-State
  • Kidney Calculi
  • Humans
  • Holmium
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Soto-Palou, F., Chen, J., Medairos, R., Zhong, P., Antonelli, J., Preminger, G. M., & Lipkin, M. E. (2023). In Pursuit of the Optimal Dusting Settings with the Thulium Fiber Laser: An In Vitro Assessment. J Endourol, 37(8), 914–920. https://doi.org/10.1089/end.2023.0168
Soto-Palou, Francois, Junqin Chen, Robert Medairos, Pei Zhong, Jodi Antonelli, Glenn M. Preminger, and Michael E. Lipkin. “In Pursuit of the Optimal Dusting Settings with the Thulium Fiber Laser: An In Vitro Assessment.J Endourol 37, no. 8 (August 2023): 914–20. https://doi.org/10.1089/end.2023.0168.
Soto-Palou F, Chen J, Medairos R, Zhong P, Antonelli J, Preminger GM, et al. In Pursuit of the Optimal Dusting Settings with the Thulium Fiber Laser: An In Vitro Assessment. J Endourol. 2023 Aug;37(8):914–20.
Soto-Palou, Francois, et al. “In Pursuit of the Optimal Dusting Settings with the Thulium Fiber Laser: An In Vitro Assessment.J Endourol, vol. 37, no. 8, Aug. 2023, pp. 914–20. Pubmed, doi:10.1089/end.2023.0168.
Soto-Palou F, Chen J, Medairos R, Zhong P, Antonelli J, Preminger GM, Lipkin ME. In Pursuit of the Optimal Dusting Settings with the Thulium Fiber Laser: An In Vitro Assessment. J Endourol. 2023 Aug;37(8):914–920.
Journal cover image

Published In

J Endourol

DOI

EISSN

1557-900X

Publication Date

August 2023

Volume

37

Issue

8

Start / End Page

914 / 920

Location

United States

Related Subject Headings

  • Urology & Nephrology
  • Urinary Calculi
  • Thulium
  • Lithotripsy, Laser
  • Lasers, Solid-State
  • Kidney Calculi
  • Humans
  • Holmium
  • 3202 Clinical sciences
  • 1103 Clinical Sciences