Image quality of photon counting and energy integrating chest CT - Prospective head-to-head comparison on same patients.

Publication ,  Journal Article
Schwartz, FR; Ria, F; McCabe, C; Zarei, M; Rajagopal, J; Molvin, L; Marin, D; O'Sullivan-Murphy, B; Kalisz, KR; Tailor, TD; Washington, L ...
Published in: Eur J Radiol
September 2023

PURPOSE: To prospectively compare the image quality of high-resolution, low-dose photon-counting detector CT (PCD-CT) with standard energy-integrating-detector CT (EID) on the same patients. METHOD: IRB-approved, prospective study; patients received same-day non-contrast CT on EID and PCD-CT (NAEOTOM Alpha, blinded) with clinical protocols. Four blinded radiologists evaluated subsegmental bronchial wall definition, noise, and overall image quality in randomized order (0 = worst; 100 = best). Cases were quantitatively compared using the average Global-Noise-Index (GNI), Noise-Power-Spectrum average frequency (fav), NPS frequency-peak (fpeak), Task-Transfer-Function-10%-frequency (f10) an adjusted detectability index (d'adj), and applied output radiation doses (CTDIvol). RESULTS: Sixty patients were prospectively imaged (27 men, mean age 67 ± 10 years, mean BMI 27.9 ± 6.5, 15.9-49.4 kg/m2). Subsegmental wall definition was rated significantly better for PCD-CT than EID (mean 71 [56-87] vs 60 [45-76]; P < 0.001), noise was rated higher for PCD-CT (48 [26-69] vs 34 [13-56]; P < 0.001). Overall image quality was rated significantly higher for PCD-CT than EID (66 [48-85] vs 61 [42-79], P = 0.008). Automated image quality measures showed similar differences for PCD-CT vs EID (mean GNI 70 ± 19 HU vs 26 ± 8 HU, fav 0.35 ± 0.02 vs 0.25 ± 0.02 mm-1, fpeak 0.07 ± 0.01 vs 0.09 ± 0.03 mm-1, f10 0.7 ± 0.08 vs 0.6 ± 0.1 mm-1, all p-values < 0.001). PCD-CT showed a 10% average d'adj increase (-49% min, 233% max). PCD-CT studies were acquired at significantly lower radiation doses than EID (mean CTDIvol 4.5 ± 2.1 vs 7.7 ± 3.2 mGy, P < 0.01). CONCLUSION: Though PCD-CT had higher measured and perceived noise, it offered equivalent or better diagnostic quality compared to EID at lower radiation doses, due to its improved resolution.

Duke Scholars

Published In

Eur J Radiol

DOI

EISSN

1872-7727

Publication Date

September 2023

Volume

166

Start / End Page

111014

Location

Ireland

Related Subject Headings

  • Tomography, X-Ray Computed
  • Prospective Studies
  • Photons
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Humans
  • Clinical Protocols
  • Aged
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Schwartz, F. R., Ria, F., McCabe, C., Zarei, M., Rajagopal, J., Molvin, L., … Samei, E. (2023). Image quality of photon counting and energy integrating chest CT - Prospective head-to-head comparison on same patients. Eur J Radiol, 166, 111014. https://doi.org/10.1016/j.ejrad.2023.111014
Schwartz, Fides R., Francesco Ria, Cindy McCabe, Mojtaba Zarei, Jayasai Rajagopal, Lior Molvin, Daniele Marin, et al. “Image quality of photon counting and energy integrating chest CT - Prospective head-to-head comparison on same patients.Eur J Radiol 166 (September 2023): 111014. https://doi.org/10.1016/j.ejrad.2023.111014.
Schwartz FR, Ria F, McCabe C, Zarei M, Rajagopal J, Molvin L, et al. Image quality of photon counting and energy integrating chest CT - Prospective head-to-head comparison on same patients. Eur J Radiol. 2023 Sep;166:111014.
Schwartz, Fides R., et al. “Image quality of photon counting and energy integrating chest CT - Prospective head-to-head comparison on same patients.Eur J Radiol, vol. 166, Sept. 2023, p. 111014. Pubmed, doi:10.1016/j.ejrad.2023.111014.
Schwartz FR, Ria F, McCabe C, Zarei M, Rajagopal J, Molvin L, Marin D, O’Sullivan-Murphy B, Kalisz KR, Tailor TD, Washington L, Henry T, Samei E. Image quality of photon counting and energy integrating chest CT - Prospective head-to-head comparison on same patients. Eur J Radiol. 2023 Sep;166:111014.
Journal cover image

Published In

Eur J Radiol

DOI

EISSN

1872-7727

Publication Date

September 2023

Volume

166

Start / End Page

111014

Location

Ireland

Related Subject Headings

  • Tomography, X-Ray Computed
  • Prospective Studies
  • Photons
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Humans
  • Clinical Protocols
  • Aged