BACKGROUND: Continuous automatic optimisation of cardiac resynchronisation therapy (CRT), stimulating only the left ventricle to fuse with intrinsic right bundle conduction (synchronised left ventricular stimulation), might offer better outcomes than conventional CRT in patients with heart failure, left bundle branch block, and normal atrioventricular conduction. This study aimed to compare clinical outcomes of adaptive CRT versus conventional CRT in patients with heart failure with intact atrioventricular conduction and left bundle branch block. METHODS: This global, prospective, randomised controlled trial was done in 227 hospitals in 27 countries across Asia, Australia, Europe, and North America. Eligible patients were aged 18 years or older with class 2-4 heart failure, an ejection fraction of 35% or less, left bundle branch block with QRS duration of 140 ms or more (male patients) or 130 ms or more (female patients), and a baseline PR interval 200 ms or less. Patients were randomly assigned (1:1) via block permutation to adaptive CRT (an algorithm providing synchronised left ventricular stimulation) or conventional biventricular CRT using a device programmer. All patients received device programming but were masked until procedures were completed. Site staff were not masked to group assignment. The primary outcome was a composite of all-cause death or intervention for heart failure decompensation and was assessed in the intention-to-treat population. Safety events were collected and reported in the intention-to-treat population. This study is registered with ClinicalTrials.gov, NCT02205359, and is closed to accrual. FINDINGS: Between Aug 5, 2014, and Jan 31, 2019, of 3797 patients enrolled, 3617 (95·3%) were randomly assigned (1810 to adaptive CRT and 1807 to conventional CRT). The futility boundary was crossed at the third interim analysis on June 23, 2022, when the decision was made to stop the trial early. 1568 (43·4%) of 3617 patients were female and 2049 (56·6%) were male. Median follow-up was 59·0 months (IQR 45-72). A primary outcome event occurred in 430 of 1810 patients (Kaplan-Meier occurrence rate 23·5% [95% CI 21·3-25·5] at 60 months) in the adaptive CRT group and in 470 of 1807 patients (25·7% [23·5-27·8] at 60 months) in the conventional CRT group (hazard ratio 0·89, 95% CI 0·78-1·01; p=0·077). System-related adverse events were reported in 452 (25·0%) of 1810 patients in the adaptive CRT group and 440 (24·3%) of 1807 patients in the conventional CRT group. INTERPRETATION: Compared with conventional CRT, adaptive CRT did not significantly reduce the incidence of all-cause death or intervention for heart failure decompensation in the included population of patients with heart failure, left bundle branch block, and intact AV conduction. Death and heart failure decompensation rates were low with both CRT therapies, suggesting a greater response to CRT occurred in this population than in patients in previous trials. FUNDING: Medtronic.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Lancet

DOI

EISSN

1474-547X

Publication Date

September 30, 2023

Volume

402

Issue

10408

Start / End Page

1147 / 1157

Location

England

Related Subject Headings

  • Treatment Outcome
  • Stroke Volume
  • Prospective Studies
  • Male
  • Humans
  • Heart Failure
  • General & Internal Medicine
  • Female
  • Electrocardiography
  • Cardiac Resynchronization Therapy
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wilkoff, B. L., Filippatos, G., Leclercq, C., Gold, M. R., Hersi, A. S., Kusano, K., … AdaptResponse investigators, . (2023). Adaptive versus conventional cardiac resynchronisation therapy in patients with heart failure (AdaptResponse): a global, prospective, randomised controlled trial. Lancet, 402(10408), 1147–1157. https://doi.org/10.1016/S0140-6736(23)00912-1
Wilkoff, Bruce L., Gerasimos Filippatos, Christophe Leclercq, Michael R. Gold, Ahmad S. Hersi, Kengo Kusano, Wilfried Mullens, et al. “Adaptive versus conventional cardiac resynchronisation therapy in patients with heart failure (AdaptResponse): a global, prospective, randomised controlled trial.Lancet 402, no. 10408 (September 30, 2023): 1147–57. https://doi.org/10.1016/S0140-6736(23)00912-1.
Wilkoff BL, Filippatos G, Leclercq C, Gold MR, Hersi AS, Kusano K, et al. Adaptive versus conventional cardiac resynchronisation therapy in patients with heart failure (AdaptResponse): a global, prospective, randomised controlled trial. Lancet. 2023 Sep 30;402(10408):1147–57.
Wilkoff, Bruce L., et al. “Adaptive versus conventional cardiac resynchronisation therapy in patients with heart failure (AdaptResponse): a global, prospective, randomised controlled trial.Lancet, vol. 402, no. 10408, Sept. 2023, pp. 1147–57. Pubmed, doi:10.1016/S0140-6736(23)00912-1.
Wilkoff BL, Filippatos G, Leclercq C, Gold MR, Hersi AS, Kusano K, Mullens W, Felker GM, Kantipudi C, El-Chami MF, Essebag V, Pierre B, Philippon F, Perez-Gil F, Chung ES, Sotomonte J, Tung S, Singh B, Bozorgnia B, Goel S, Ebert HH, Varma N, Quan KJ, Salerno F, Gerritse B, van Wel J, Schaber DE, Fagan DH, Birnie D, AdaptResponse investigators. Adaptive versus conventional cardiac resynchronisation therapy in patients with heart failure (AdaptResponse): a global, prospective, randomised controlled trial. Lancet. 2023 Sep 30;402(10408):1147–1157.
Journal cover image

Published In

Lancet

DOI

EISSN

1474-547X

Publication Date

September 30, 2023

Volume

402

Issue

10408

Start / End Page

1147 / 1157

Location

England

Related Subject Headings

  • Treatment Outcome
  • Stroke Volume
  • Prospective Studies
  • Male
  • Humans
  • Heart Failure
  • General & Internal Medicine
  • Female
  • Electrocardiography
  • Cardiac Resynchronization Therapy