Accuracy and Feasibility of Three-Dimensional Ultrasound Testing in Eye Clinic and Emergency Department Patients with Vision Complaints.

Publication ,  Journal Article
Theophanous, RG; Gordee, A; Peethumnongsin, E; Huang, W; Gurysh, K; Coco, M; Campos, SC; Ruderman, B; Kuchibhatla, M; Broder, J
Published in: J Emerg Med
February 2024

BACKGROUND: Ocular emergencies comprise 2-3% of emergency department (ED) visits, with retinal detachment requiring emergency surgery. Two-dimensional ultrasound is a rapid bedside tool but is highly operator dependent. OBJECTIVE: We determined three-dimensional ultrasound (3DUS) feasibility, acceptability, and usability in eye pathology detection using the ophthalmologist examination as reference standard. METHODS: We performed a prospective, blinded cohort study of a 3DUS-enabling device in 30 eye clinic and ED patients with visual symptoms and calculated 3DUS performance characteristics. Two expert readers interpreted the 3DUS images for pathology. All participants completed surveys. RESULTS: 3DUS sensitivity was 0.81, specificity 0.73, positive predictive value 0.54, negative predictive value 0.91, and likelihood ratio (LR)+/LR- 3.03 and 0.26, respectively. Novice and expert sonographers had "substantial" agreement in correct diagnosis of abnormal vs. normal (κ = 0.68, 95% confidence interval 0.48-0.88). Most patients indicated that 3DUS is fast, comfortable, helps them understand their problem, and improves provider interaction/care, and all sonographers agreed; 4/5 sonographers felt confident performing ultrasound. Expert readers correctly identified an abnormal eye in 83/120 scans (76%) and correct diagnosis in 72/120 scans (65%), with no statistical difference between novice (79%; 69%) and expert (72%; 61%) sonographers (p = 0.39, p = 0.55), suggesting reduced operator dependence. Reader diagnosis confidence and image quality varied widely. Image acquisition times were fast for novice (mean 225 ± 83 s) and expert (201 ± 51) sonographers, with fast expert reader interpretation times (225 ± 136). CONCLUSIONS: A 3DUS-enabling device demonstrates a sensitivity of 0.81 and specificity of 0.73 for disease detection, fast image acquisition, and may reduce operator dependence for detecting emergent retinal pathologies. Further technological development is needed to improve diagnostic accuracy in identifying and characterizing retinal pathology.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Emerg Med

DOI

ISSN

0736-4679

Publication Date

February 2024

Volume

66

Issue

2

Start / End Page

197 / 210

Location

United States

Related Subject Headings

  • Ultrasonography
  • Sensitivity and Specificity
  • Prospective Studies
  • Humans
  • Feasibility Studies
  • Emergency Service, Hospital
  • Emergency & Critical Care Medicine
  • Cohort Studies
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Theophanous, R. G., Gordee, A., Peethumnongsin, E., Huang, W., Gurysh, K., Coco, M., … Broder, J. (2024). Accuracy and Feasibility of Three-Dimensional Ultrasound Testing in Eye Clinic and Emergency Department Patients with Vision Complaints. J Emerg Med, 66(2), 197–210. https://doi.org/10.1016/j.jemermed.2023.10.032
Theophanous, Rebecca G., Alexander Gordee, Erica Peethumnongsin, Wennie Huang, Kevin Gurysh, Matthew Coco, Santiago Cantillo Campos, Brandon Ruderman, Maragatha Kuchibhatla, and Joshua Broder. “Accuracy and Feasibility of Three-Dimensional Ultrasound Testing in Eye Clinic and Emergency Department Patients with Vision Complaints.J Emerg Med 66, no. 2 (February 2024): 197–210. https://doi.org/10.1016/j.jemermed.2023.10.032.
Theophanous RG, Gordee A, Peethumnongsin E, Huang W, Gurysh K, Coco M, et al. Accuracy and Feasibility of Three-Dimensional Ultrasound Testing in Eye Clinic and Emergency Department Patients with Vision Complaints. J Emerg Med. 2024 Feb;66(2):197–210.
Theophanous, Rebecca G., et al. “Accuracy and Feasibility of Three-Dimensional Ultrasound Testing in Eye Clinic and Emergency Department Patients with Vision Complaints.J Emerg Med, vol. 66, no. 2, Feb. 2024, pp. 197–210. Pubmed, doi:10.1016/j.jemermed.2023.10.032.
Theophanous RG, Gordee A, Peethumnongsin E, Huang W, Gurysh K, Coco M, Campos SC, Ruderman B, Kuchibhatla M, Broder J. Accuracy and Feasibility of Three-Dimensional Ultrasound Testing in Eye Clinic and Emergency Department Patients with Vision Complaints. J Emerg Med. 2024 Feb;66(2):197–210.
Journal cover image

Published In

J Emerg Med

DOI

ISSN

0736-4679

Publication Date

February 2024

Volume

66

Issue

2

Start / End Page

197 / 210

Location

United States

Related Subject Headings

  • Ultrasonography
  • Sensitivity and Specificity
  • Prospective Studies
  • Humans
  • Feasibility Studies
  • Emergency Service, Hospital
  • Emergency & Critical Care Medicine
  • Cohort Studies
  • 3202 Clinical sciences
  • 1103 Clinical Sciences