Skip to main content

Assessing the Diagnostic Accuracy of Next-Generation Sequencing in Patients With Antibiotic Spacers Before Reimplantation.

Publication ,  Journal Article
Kildow, BJ; Cochrane, N; Kelly, PJ; O'Donnell, JA; Wu, M; Lyden, E; Jiranek, WA; Seyler, TM
Published in: Orthopedics
2024

Use of molecular sequencing modalities in periprosthetic joint infection diagnosis and organism identification has gained popularity recently. To date, there is no diagnostic test that reliably predicts infection eradication in patients with antibiotic spacers. The purpose of this study was to compare the diagnostic accuracy of next-generation sequencing (NGS), culture, the Musculoskeletal Infection Society (MSIS) criteria, and the criteria by Parvizi et al in patients with antibiotic spacers. In this retrospective study, aspirate or tissue samples were collected from 38 knee and 19 hip antibiotic spacers for routine diagnostic workup for the presence of persistent infection and sent to the laboratory for NGS. The kappa statistic along with statistical differences between diagnostic studies were calculated using the chi-square test for categorical data. The kappa coefficient for agreement between NGS and culture was 0.27 (fair agreement). The percentages of positive and negative agreement were 22.8% and 42.1%, respectively, with a total concordance of 64.9%. There were 12 samples that were culture positive and NGS negative. Eight samples were NGS positive but culture negative. The kappa coefficient was 0.42 (moderate agreement) when comparing NGS with MSIS criteria. In our series, NGS did not provide sufficient agreement compared with culture or MSIS criteria in the setting of an antibiotic spacer. A reliable diagnostic indicator for reimplantation has yet to be identified. [Orthopedics. 2024;47(1);46-51.].

Duke Scholars

Published In

Orthopedics

DOI

EISSN

1938-2367

Publication Date

2024

Volume

47

Issue

1

Start / End Page

46 / 51

Location

United States

Related Subject Headings

  • Retrospective Studies
  • Replantation
  • Reoperation
  • Prosthesis-Related Infections
  • Orthopedics
  • Humans
  • Hip Prosthesis
  • High-Throughput Nucleotide Sequencing
  • Arthroplasty, Replacement, Hip
  • Anti-Bacterial Agents
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Kildow, B. J., Cochrane, N., Kelly, P. J., O’Donnell, J. A., Wu, M., Lyden, E., … Seyler, T. M. (2024). Assessing the Diagnostic Accuracy of Next-Generation Sequencing in Patients With Antibiotic Spacers Before Reimplantation. Orthopedics, 47(1), 46–51. https://doi.org/10.3928/01477447-20230426-09
Kildow, Beau J., Niall Cochrane, Patrick J. Kelly, Jeffrey A. O’Donnell, Mark Wu, Elizabeth Lyden, William A. Jiranek, and Thorsten M. Seyler. “Assessing the Diagnostic Accuracy of Next-Generation Sequencing in Patients With Antibiotic Spacers Before Reimplantation.Orthopedics 47, no. 1 (2024): 46–51. https://doi.org/10.3928/01477447-20230426-09.
Kildow BJ, Cochrane N, Kelly PJ, O’Donnell JA, Wu M, Lyden E, et al. Assessing the Diagnostic Accuracy of Next-Generation Sequencing in Patients With Antibiotic Spacers Before Reimplantation. Orthopedics. 2024;47(1):46–51.
Kildow, Beau J., et al. “Assessing the Diagnostic Accuracy of Next-Generation Sequencing in Patients With Antibiotic Spacers Before Reimplantation.Orthopedics, vol. 47, no. 1, 2024, pp. 46–51. Pubmed, doi:10.3928/01477447-20230426-09.
Kildow BJ, Cochrane N, Kelly PJ, O’Donnell JA, Wu M, Lyden E, Jiranek WA, Seyler TM. Assessing the Diagnostic Accuracy of Next-Generation Sequencing in Patients With Antibiotic Spacers Before Reimplantation. Orthopedics. 2024;47(1):46–51.

Published In

Orthopedics

DOI

EISSN

1938-2367

Publication Date

2024

Volume

47

Issue

1

Start / End Page

46 / 51

Location

United States

Related Subject Headings

  • Retrospective Studies
  • Replantation
  • Reoperation
  • Prosthesis-Related Infections
  • Orthopedics
  • Humans
  • Hip Prosthesis
  • High-Throughput Nucleotide Sequencing
  • Arthroplasty, Replacement, Hip
  • Anti-Bacterial Agents