Skip to main content
Journal cover image

Validation of complex radiotherapy techniques using polymer gel dosimetry.

Publication ,  Journal Article
Karger, CP; Elter, A; Dorsch, S; Mann, P; Pappas, E; Oldham, M
Published in: Phys Med Biol
March 20, 2024

Modern radiotherapy delivers highly conformal dose distributions to irregularly shaped target volumes while sparing the surrounding normal tissue. Due to the complex planning and delivery techniques, dose verification and validation of the whole treatment workflow by end-to-end tests became much more important and polymer gel dosimeters are one of the few possibilities to capture the delivered dose distribution in 3D. The basic principles and formulations of gel dosimetry and its evaluation methods are described and the available studies validating device-specific geometrical parameters as well as the dose delivery by advanced radiotherapy techniques, such as 3D-CRT/IMRT and stereotactic radiosurgery treatments, the treatment of moving targets, online-adaptive magnetic resonance-guided radiotherapy as well as proton and ion beam treatments, are reviewed. The present status and limitations as well as future challenges of polymer gel dosimetry for the validation of complex radiotherapy techniques are discussed.

Duke Scholars

Published In

Phys Med Biol

DOI

EISSN

1361-6560

Publication Date

March 20, 2024

Volume

69

Issue

6

Location

England

Related Subject Headings

  • Radiotherapy, Conformal
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Radiometry
  • Polymers
  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 1103 Clinical Sciences
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Karger, C. P., Elter, A., Dorsch, S., Mann, P., Pappas, E., & Oldham, M. (2024). Validation of complex radiotherapy techniques using polymer gel dosimetry. Phys Med Biol, 69(6). https://doi.org/10.1088/1361-6560/ad278f
Karger, Christian P., Alina Elter, Stefan Dorsch, Philipp Mann, Evangelos Pappas, and Mark Oldham. “Validation of complex radiotherapy techniques using polymer gel dosimetry.Phys Med Biol 69, no. 6 (March 20, 2024). https://doi.org/10.1088/1361-6560/ad278f.
Karger CP, Elter A, Dorsch S, Mann P, Pappas E, Oldham M. Validation of complex radiotherapy techniques using polymer gel dosimetry. Phys Med Biol. 2024 Mar 20;69(6).
Karger, Christian P., et al. “Validation of complex radiotherapy techniques using polymer gel dosimetry.Phys Med Biol, vol. 69, no. 6, Mar. 2024. Pubmed, doi:10.1088/1361-6560/ad278f.
Karger CP, Elter A, Dorsch S, Mann P, Pappas E, Oldham M. Validation of complex radiotherapy techniques using polymer gel dosimetry. Phys Med Biol. 2024 Mar 20;69(6).
Journal cover image

Published In

Phys Med Biol

DOI

EISSN

1361-6560

Publication Date

March 20, 2024

Volume

69

Issue

6

Location

England

Related Subject Headings

  • Radiotherapy, Conformal
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Radiometry
  • Polymers
  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 1103 Clinical Sciences
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences