Clinical Applications and Monte Carlo Validation of a fully integrated 3D dosimetry system

Publication ,  Conference
Lakrad, K; Quinn, B; Oldham, M; Adamson, J
Published in: Journal of Physics: Conference Series
January 1, 2024

A comprehensive 3D dosimetry system consisting of the ClearView™ 3D dosimeter, VistaScan™ optical CT scanner, and VistaAce™ analysis software is commercially available and has the potential to be a strong verification tool with widespread applications. The clinical utility of this system (termed ClearView/Vista) has yet to be determined, and this work presents our first investigation. Clinical utility was evaluated using real patients' treatment plans: spine, head and neck, Single Isocenter Multi-Targets SRS (SIMT-SRS), and prostate cases. Independent validation was performed with a Monte Carlo-based dose calculation algorithm that was previously commissioned for clinical independent dose calculation. The analysis included line profile comparison (1D), isodose line comparison (2D), and global gamma analysis (3D). Results indicated a remarkable agreement between ClearView/Vista, the treatment planning system, and Monte Carlo, where gamma pass rates for all cases exceeded 94% even while using 2%2mm and a dose threshold of 10%. The ClearView/Vista 3D dosimetry system showed clinically acceptable accuracy and robust measurement and analysis in clinical settings.

Duke Scholars

Published In

Journal of Physics: Conference Series

DOI

EISSN

1742-6596

ISSN

1742-6588

Publication Date

January 1, 2024

Volume

2799

Issue

1

Related Subject Headings

  • 51 Physical sciences
  • 0299 Other Physical Sciences
  • 0204 Condensed Matter Physics
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Lakrad, K., Quinn, B., Oldham, M., & Adamson, J. (2024). Clinical Applications and Monte Carlo Validation of a fully integrated 3D dosimetry system. In Journal of Physics: Conference Series (Vol. 2799). https://doi.org/10.1088/1742-6596/2799/1/012011
Lakrad, K., B. Quinn, M. Oldham, and J. Adamson. “Clinical Applications and Monte Carlo Validation of a fully integrated 3D dosimetry system.” In Journal of Physics: Conference Series, Vol. 2799, 2024. https://doi.org/10.1088/1742-6596/2799/1/012011.
Lakrad K, Quinn B, Oldham M, Adamson J. Clinical Applications and Monte Carlo Validation of a fully integrated 3D dosimetry system. In: Journal of Physics: Conference Series. 2024.
Lakrad, K., et al. “Clinical Applications and Monte Carlo Validation of a fully integrated 3D dosimetry system.” Journal of Physics: Conference Series, vol. 2799, no. 1, 2024. Scopus, doi:10.1088/1742-6596/2799/1/012011.
Lakrad K, Quinn B, Oldham M, Adamson J. Clinical Applications and Monte Carlo Validation of a fully integrated 3D dosimetry system. Journal of Physics: Conference Series. 2024.
Journal cover image

Published In

Journal of Physics: Conference Series

DOI

EISSN

1742-6596

ISSN

1742-6588

Publication Date

January 1, 2024

Volume

2799

Issue

1

Related Subject Headings

  • 51 Physical sciences
  • 0299 Other Physical Sciences
  • 0204 Condensed Matter Physics
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics