Evaluating the Accuracy of a Computed Tomography-Based Mixed-Reality Navigation Tool for Acetabular Component Positioning in Total Hip Arthroplasty.

Publication ,  Journal Article
Dilbone, ES; Heimann, AF; Leal, J; Ryan, SP; Wellman, SS
Published in: J Arthroplasty
February 13, 2025

BACKGROUND: Robotics and navigation systems have improved the accuracy and precision of acetabular component placement in total hip arthroplasty (THA). The purpose of this study was to determine if the intraoperative use of a novel mixed-reality (MR) navigation system resulted in accurate acetabular component placement with minimal outliers. METHODS: A series of 79 patients who underwent THA performed by a single surgeon using a novel MR navigation system were retrospectively reviewed. The preoperative planned acetabular component operative inclination (OI) and tilt-adjusted operative anteversion (OA) were collected for each case. At the six-week follow-up, each patient underwent three-dimensional EOS imaging, which was used to measure the acetabular component placement via validated measuring software. Patients who had bilateral THAs or three-dimensional images that did not have critical bony landmarks visible for measurement were excluded from the study. Absolute error was calculated for both inclination and anteversion. Outliers were defined as any cup position that was outside a range of ± 10 degrees from the preoperatively planned target. A total of 39 patients met the inclusion criteria. RESULTS: The mean planned OI for each patient was 40.8 (range, 40 to 41) degrees, and the mean measured postoperative OI was 40.4 (range, 37 to 46) degrees (P = 0.40), resulting in a mean absolute error of 1.8 (range, zero to five) degrees. The mean planned OA was 30.2 (range, 25 to 35) degrees, and the mean measured postoperative OA was 31.1 (range, 27 to 42) degrees (P = 0.11), resulting in a mean absolute error of 2.0 (range, zero to six) degrees. There were no outliers in either OI or OA. CONCLUSIONS: The results of this study suggest that the use of MR navigation during THA results in accurate postoperative acetabular component inclination and anteversion relative to the preoperative plan without outliers.

Duke Scholars

Published In

J Arthroplasty

DOI

EISSN

1532-8406

Publication Date

February 13, 2025

Location

United States

Related Subject Headings

  • Orthopedics
  • 4003 Biomedical engineering
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Dilbone, E. S., Heimann, A. F., Leal, J., Ryan, S. P., & Wellman, S. S. (2025). Evaluating the Accuracy of a Computed Tomography-Based Mixed-Reality Navigation Tool for Acetabular Component Positioning in Total Hip Arthroplasty. J Arthroplasty. https://doi.org/10.1016/j.arth.2025.02.003
Dilbone, Eric S., Alexander F. Heimann, Justin Leal, Sean P. Ryan, and Samuel S. Wellman. “Evaluating the Accuracy of a Computed Tomography-Based Mixed-Reality Navigation Tool for Acetabular Component Positioning in Total Hip Arthroplasty.J Arthroplasty, February 13, 2025. https://doi.org/10.1016/j.arth.2025.02.003.
Journal cover image

Published In

J Arthroplasty

DOI

EISSN

1532-8406

Publication Date

February 13, 2025

Location

United States

Related Subject Headings

  • Orthopedics
  • 4003 Biomedical engineering
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
  • 0903 Biomedical Engineering