Skip to main content
release_alert
Welcome to the new Scholars 3.0! Read about new features and let us know what you think.
cancel

Diffusion-weighted MR imaging of the normal human spinal cord in vivo.

Publication ,  Journal Article
Holder, CA; Muthupillai, R; Mukundan, S; Eastwood, JD; Hudgins, PA
Published in: Ajnr Am J Neuroradiol
2000

BACKGROUND AND PURPOSE: Diffusion-weighted imaging is a robust technique for evaluation of a variety of neurologic diseases affecting the brain, and might also have applications in the spinal cord. The purpose of this study was to determine the feasibility of obtaining in vivo diffusion-weighted images of the human spinal cord, to calculate normal apparent diffusion coefficient (ADC) values, and to assess cord anisotropy. METHODS: Fifteen healthy volunteers were imaged using a multi-shot, navigator-corrected, spin-echo, echo-planar pulse sequence. Axial images of the cervical spinal cord were obtained with diffusion gradients applied along three orthogonal axes (6 b values each), and ADC values were calculated for white and gray matter. RESULTS: With the diffusion gradients perpendicular to the orientation of the white matter tracts, spinal cord white matter was hyperintense to central gray matter at all b values. This was also the case at low b values with the diffusion gradients parallel to the white matter tracts; however, at higher b values, the relative signal intensity of gray and white matter reversed. With the diffusion gradients perpendicular to spinal cord, mean ADC values ranged from 0.40 to 0.57 x 10(-3) mm2/s for white and gray matter. With the diffusion gradients parallel to the white matter tracts, calculated ADC values were significantly higher. There was a statistically significant difference between the ADCs of white versus gray matter with all three gradient directions. Strong diffusional anisotropy was observed in spinal cord white matter. CONCLUSION: Small field-of-view diffusion-weighted images of the human spinal cord can be acquired in vivo with reasonable scan times. Diffusion within spinal cord white matter is highly anisotropic.

Duke Scholars

Published In

Ajnr Am J Neuroradiol

ISSN

0195-6108

Publication Date

2000

Volume

21

Issue

10

Start / End Page

1799 / 1806

Location

United States

Related Subject Headings

  • Spinal Cord
  • Nuclear Medicine & Medical Imaging
  • Male
  • Image Processing, Computer-Assisted
  • Humans
  • Female
  • Echo-Planar Imaging
  • Anisotropy
  • Adult
  • 1109 Neurosciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Holder, C. A., Muthupillai, R., Mukundan, S., Eastwood, J. D., & Hudgins, P. A. (2000). Diffusion-weighted MR imaging of the normal human spinal cord in vivo. Ajnr Am J Neuroradiol, 21(10), 1799–1806.
Holder, C. A., R. Muthupillai, S. Mukundan, J. D. Eastwood, and P. A. Hudgins. “Diffusion-weighted MR imaging of the normal human spinal cord in vivo.Ajnr Am J Neuroradiol 21, no. 10 (2000): 1799–1806.
Holder CA, Muthupillai R, Mukundan S, Eastwood JD, Hudgins PA. Diffusion-weighted MR imaging of the normal human spinal cord in vivo. Ajnr Am J Neuroradiol. 2000;21(10):1799–806.
Holder, C. A., et al. “Diffusion-weighted MR imaging of the normal human spinal cord in vivo.Ajnr Am J Neuroradiol, vol. 21, no. 10, 2000, pp. 1799–806.
Holder CA, Muthupillai R, Mukundan S, Eastwood JD, Hudgins PA. Diffusion-weighted MR imaging of the normal human spinal cord in vivo. Ajnr Am J Neuroradiol. 2000;21(10):1799–1806.

Published In

Ajnr Am J Neuroradiol

ISSN

0195-6108

Publication Date

2000

Volume

21

Issue

10

Start / End Page

1799 / 1806

Location

United States

Related Subject Headings

  • Spinal Cord
  • Nuclear Medicine & Medical Imaging
  • Male
  • Image Processing, Computer-Assisted
  • Humans
  • Female
  • Echo-Planar Imaging
  • Anisotropy
  • Adult
  • 1109 Neurosciences