Skip to main content
Journal cover image

The effects of heparin anticoagulants and fill volume in blood gas syringes on ionized calcium and magnesium measurements.

Publication ,  Journal Article
Toffaletti, JG; Wildermann, RF
Published in: Clin Chim Acta
February 2001

We studied the effects of several heparin anticoagulants on ionized calcium and ionized magnesium measurements. Venous blood from 24 healthy donors was drawn into 20-ml syringes without an anticoagulant, and immediately analyzed for control results. They were then transferred to completely fill and half-fill each of four brands of syringes, and an evacuated non-anticoagulated blood-collection tube. All were analyzed for ionized calcium and magnesium. In some cases, either saline or a Ca/Mg solution was added to increase the range of concentrations. The final concentrations ranged from 0.94 to 2.09 (ionized calcium) and from 0.41 to 1.06 mmol/l (ionized magnesium). In full syringes, mean changes in ionized calcium or magnesium were <0.01 mmol/l over a range of concentrations usually encountered. The only definite effect was noted in half-full Martell syringes, where ionized calcium was lower by 0.028 mmol/l. At very high ionized calcium concentrations (>1.95 mmol/l) and ionized magnesium concentrations (>0.95 mmol/l), a few changes were noted of little clinical significance. We conclude that all the syringes evaluated have no clinically significant effects on ionized calcium or ionized magnesium concentrations when filled to capacity. When half-full, a few changes of marginal clinical significance were noted. All these effects were less than observed in serum, which is apparently affected by sample processing and/or clotting.

Duke Scholars

Published In

Clin Chim Acta

DOI

ISSN

0009-8981

Publication Date

February 2001

Volume

304

Issue

1-2

Start / End Page

147 / 151

Location

Netherlands

Related Subject Headings

  • Magnesium
  • Humans
  • Heparin
  • General Clinical Medicine
  • Calcium
  • Anticoagulants
  • 3202 Clinical sciences
  • 3101 Biochemistry and cell biology
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Toffaletti, J. G., & Wildermann, R. F. (2001). The effects of heparin anticoagulants and fill volume in blood gas syringes on ionized calcium and magnesium measurements. Clin Chim Acta, 304(1–2), 147–151. https://doi.org/10.1016/s0009-8981(00)00412-5
Toffaletti, J. G., and R. F. Wildermann. “The effects of heparin anticoagulants and fill volume in blood gas syringes on ionized calcium and magnesium measurements.Clin Chim Acta 304, no. 1–2 (February 2001): 147–51. https://doi.org/10.1016/s0009-8981(00)00412-5.
Toffaletti, J. G., and R. F. Wildermann. “The effects of heparin anticoagulants and fill volume in blood gas syringes on ionized calcium and magnesium measurements.Clin Chim Acta, vol. 304, no. 1–2, Feb. 2001, pp. 147–51. Pubmed, doi:10.1016/s0009-8981(00)00412-5.
Journal cover image

Published In

Clin Chim Acta

DOI

ISSN

0009-8981

Publication Date

February 2001

Volume

304

Issue

1-2

Start / End Page

147 / 151

Location

Netherlands

Related Subject Headings

  • Magnesium
  • Humans
  • Heparin
  • General Clinical Medicine
  • Calcium
  • Anticoagulants
  • 3202 Clinical sciences
  • 3101 Biochemistry and cell biology
  • 1103 Clinical Sciences