Skip to main content

Ion microanalysis of cells.

Publication ,  Journal Article
Linton, RW; Walker, SR; DeVries, CR; Ingram, P; Shelburne, JD
Published in: Scan Electron Microsc
1980

The application of ion microanalysis (IMA) to the chemical characterization of freeze-fixed, freeze-dried cells is reviewed. Particular emphasis is given to pathological studies involving the determination of the chemical composition of isolated cells (e.g. rabbit alveolar macrophages--RAMs) exposed in vitro to toxic species (e.g. Pb3O4 particles). Ion microscopic results indicated that lead from Pb3O4 migrated into the RAMs and subsequently formed phosphorous-containing compounds. Quantitative comparisons of the relative concentrations of physiologic elements in Pb3O4-treated versus control RAMs also were made using ion microanalytical techniques. The Pb3O4 results illustrate that the three-dimensional analysis capabilities of the IMA may be exploited for the in situ observation of the penetration of xenobiotic agents into cell interiors and their subsequent intracellular chemistry. The potential advantages of ion microanalysis for the characterization of cells include high elemental sensitivity (including low atomic number elements and diffusible ions), broad elemental coverage, three dimensional analysis, and isotopic information. The major limitations include non-idealities of the ion sputtering process, the constraints on the lateral resolution available to identify subcellular features, and the difficulties inherent in the determination of absolute elemental concentrations.

Duke Scholars

Published In

Scan Electron Microsc

ISSN

0586-5581

Publication Date

1980

Issue

Pt 2

Start / End Page

583 / 596

Location

United States

Related Subject Headings

  • Rabbits
  • Phosphorus
  • Microscopy, Electron
  • Mass Spectrometry
  • Macrophages
  • Lead
  • Ions
  • Freezing
  • Elements
  • Cytological Techniques
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Linton, R. W., Walker, S. R., DeVries, C. R., Ingram, P., & Shelburne, J. D. (1980). Ion microanalysis of cells. Scan Electron Microsc, (Pt 2), 583–596.
Linton, R. W., S. R. Walker, C. R. DeVries, P. Ingram, and J. D. Shelburne. “Ion microanalysis of cells.Scan Electron Microsc, no. Pt 2 (1980): 583–96.
Linton RW, Walker SR, DeVries CR, Ingram P, Shelburne JD. Ion microanalysis of cells. Scan Electron Microsc. 1980;(Pt 2):583–96.
Linton, R. W., et al. “Ion microanalysis of cells.Scan Electron Microsc, no. Pt 2, 1980, pp. 583–96.
Linton RW, Walker SR, DeVries CR, Ingram P, Shelburne JD. Ion microanalysis of cells. Scan Electron Microsc. 1980;(Pt 2):583–596.

Published In

Scan Electron Microsc

ISSN

0586-5581

Publication Date

1980

Issue

Pt 2

Start / End Page

583 / 596

Location

United States

Related Subject Headings

  • Rabbits
  • Phosphorus
  • Microscopy, Electron
  • Mass Spectrometry
  • Macrophages
  • Lead
  • Ions
  • Freezing
  • Elements
  • Cytological Techniques