Electric field of a six-needle array electrode used in drug and DNA delivery in vivo: analytical versus numerical solution.

Publication ,  Journal Article
Dev, SB; Dhar, D; Krassowska, W
Published in: IEEE transactions on bio-medical engineering
November 2003

We present an analytical solution for the electrical potential and field established by a six-needle array electroporation electrode, which is used in vivo for cancer treatment and DNA delivery. The analytical solution closely matches the numerical solution obtained with the finite element method: the mean error is less than 0.6%.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

IEEE transactions on bio-medical engineering

DOI

EISSN

1558-2531

ISSN

0018-9294

Publication Date

November 2003

Volume

50

Issue

11

Start / End Page

1296 / 1300

Related Subject Headings

  • Transfection
  • Radiometry
  • Needles
  • Models, Biological
  • Genetic Therapy
  • Finite Element Analysis
  • Equipment Failure Analysis
  • Electroporation
  • Electromagnetic Fields
  • Electrodes
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Dev, S. B., Dhar, D., & Krassowska, W. (2003). Electric field of a six-needle array electrode used in drug and DNA delivery in vivo: analytical versus numerical solution. IEEE Transactions on Bio-Medical Engineering, 50(11), 1296–1300. https://doi.org/10.1109/tbme.2003.818467
Dev, Sukhendu B., Deepak Dhar, and Wanda Krassowska. “Electric field of a six-needle array electrode used in drug and DNA delivery in vivo: analytical versus numerical solution.IEEE Transactions on Bio-Medical Engineering 50, no. 11 (November 2003): 1296–1300. https://doi.org/10.1109/tbme.2003.818467.
Dev SB, Dhar D, Krassowska W. Electric field of a six-needle array electrode used in drug and DNA delivery in vivo: analytical versus numerical solution. IEEE transactions on bio-medical engineering. 2003 Nov;50(11):1296–300.
Dev, Sukhendu B., et al. “Electric field of a six-needle array electrode used in drug and DNA delivery in vivo: analytical versus numerical solution.IEEE Transactions on Bio-Medical Engineering, vol. 50, no. 11, Nov. 2003, pp. 1296–300. Epmc, doi:10.1109/tbme.2003.818467.
Dev SB, Dhar D, Krassowska W. Electric field of a six-needle array electrode used in drug and DNA delivery in vivo: analytical versus numerical solution. IEEE transactions on bio-medical engineering. 2003 Nov;50(11):1296–1300.

Published In

IEEE transactions on bio-medical engineering

DOI

EISSN

1558-2531

ISSN

0018-9294

Publication Date

November 2003

Volume

50

Issue

11

Start / End Page

1296 / 1300

Related Subject Headings

  • Transfection
  • Radiometry
  • Needles
  • Models, Biological
  • Genetic Therapy
  • Finite Element Analysis
  • Equipment Failure Analysis
  • Electroporation
  • Electromagnetic Fields
  • Electrodes